REFERENCE CLOCK (OPTIONAL)
A reference clock is not required to perform clock and data
recovery with the ADN2806; however, support for an optional
reference clock is provided. The reference clock can be driven
differentially or in a single-ended fashion. If the reference
clock is not being used, REFCLKP should be tied to VCC, and
REFCLKN can be left floating or tied to VEE (the inputs are
internally terminated to VCC/2). See Figure 16 through Figure
18 for sample configurations.
The REFCLK input buffer accepts any differential signal with a
peak-to-peak differential amplitude of greater than 100 mV (for
example, LVPECL or LVDS) or a standard single-ended, low
voltage TTL input, providing maximum system flexibility.
Phase noise and duty cycle of the reference clock are not
critical, and 100 ppm accuracy is sufficient.
VCC
CLK
OSC
NC
Figure 17. Single-Ended REFCLK Configuration
VCC
Figure 16. Differential REFCLK Configuration
OUT
REFCLKN
REFCLKP
REFCLKP
REFCLKN
Figure 18. No REFCLK Configuration
REFCLKP
REFCLKN
10
11
10
11
ADN2806
ADN2806
100kΩ
ADN2806
100kΩ
100kΩ
100kΩ
100kΩ
BUFFER
BUFFER
100kΩ
BUFFER
VCC/2
VCC/2
VCC/2
Rev. 0 | Page 15 of 20
There are two mutually exclusive uses, or modes, of the
reference clock. The reference clock can be used either to help
the ADN2806 lock onto data or to measure the frequency of the
incoming data to within 0.01%. The modes are mutually
exclusive because in the first use the user knows exactly what
the data rate is and wants to force the part to lock onto only that
data rate, and in the second use the user does not know what
the data rate is and wants to measure it.
Lock-to-reference mode is enabled by writing a 1 to I
Bit CTRLA[0]. Fine data rate readback mode is enabled by
writing a 1 to I
these bits at the same time causes an indeterminate state and is
not supported.
Using the Reference Clock to Lock onto Data
In this mode, the ADN2806 locks onto a frequency derived
from the reference clock according to
The user must provide a reference clock that is a function of the
data rate. By default, the ADN2806 expects a reference clock of
19.44 MHz. Other options are 38.88 MHz, 77.76 MHz, and
155.52 MHz, which are selected by programming CTRLA[7, 6].
CTRLA[5:2] should be programmed to [0101] for all cases.
Table 11. CTRLA Settings
CTRLA[7, 6]
00
01
10
11
For example, if the reference clock frequency is 38.88 MHz and the
input data rate is 622.08 Mbps, CTRLA[7, 6] is set to [01] to
produce a divided-down reference clock of 19.44 MHz, and
CTRLA[5:2] is set to [0101], that is, 5, because
In this mode, if the ADN2806 loses lock for any reason, it relocks
onto the reference clock and continues to output a stable clock.
While the ADN2806 is operating in lock-to-reference mode,
a 0 to 1 transition should be written into the CTRLA[0] bit to
initiate a lock-to-reference clock command.
Data Rate/2
622.08 Mbps/19.44 MHz = 2
2
C Register Bit CTRLA[1]. Writing a 1 to both of
Range (MHz)
19.44
38.88
77.76
155.52
CTRLA[5:2]
= REFCLK/2
5
CTRLA[7, 6]
CTRLA[5:2]
0101
0101
0101
0101
ADN2806
2
C Register
Ratio
2
2
2
2
5
5
5
5