4.10.5.5 Line Based CRC Error Detection
4.10.5.6 HD Line Number Error Detection
4.10.5.7 TRS Error Detection
4.10.6 Error Correction and Insertion
The GS1559 will calculate line based CRC words for HD video signals for both the
Y and C data channels. These calculated CRC values are compared with the
received CRC values and any mismatch is flagged in the YCRC_ERR and/or
CCRC_ERR bits of the ERROR_STATUS register.
Line based CRC error flags will only be generated when the device is operating in
HD mode, (SD/HD = LOW).
If a CRC error is detected in the Y channel, the YCRC_ERR bit in the error status
register will be set HIGH. If a CRC error is detected in the C channel, the
CCRC_ERR bit in the error status register is set HIGH. Y and C CRC errors will
also be generated if CRC values are not received.
When operating in HD mode, the GS1559 will calculate line numbers based on the
timing generated by the internal flywheel. These calculated line numbers are
compared with the received line numbers for the Y channel data and any mismatch
is flagged in the LNUM_ERR bit of the ERROR_STATUS.
Line number errors will also be generated if line number values are not received.
TRS errors flags are generated by the GS1559 when:
1. The received TRS timing does not correspond to the internal flywheel timing;
2. The received TRS hamming codes are incorrect.
Both 8-bit and 10-bit SAV and EAV TRS words are checked for timing and data
integrity errors. These are flagged via the SAV_ERR and/or EAV_ERR bits of the
ERROR_STATUS register.
Timing-based TRS errors will only be generated if the FW_EN/DIS pin is set HIGH.
NOTE: In HD mode, (SD/HD = LOW), only the Y channel TRS codes will be
checked for errors.
In addition to signal error detection and indication, the GS1559 may also correct
certain types of errors by inserting corrected code words, checksums and CRC
values into the data stream. These features are only available in SMPTE mode and
IOPROC_EN/
or disabled via the IOPROC_DISABLE register
All of the IOPROC_DISABLE register bits default to '0' after device reset, enabling
all of the processing features. To disable any individual error correction feature, the
host interface must set the corresponding bit HIGH in the IOPROC_DISABLE
register.
Proprietary and Confidential
or
DIS
must be set HIGH. Individual correction features may be enabled
30572 - 1