SSD1859 Solomon Systech, SSD1859 Datasheet - Page 23

no-image

SSD1859

Manufacturer Part Number
SSD1859
Description
128 x 80 STN LCD Segment / Common 4 G/S Drive
Manufacturer
Solomon Systech
Datasheet
SSD1859
Hex
A8~A9
AA
AB
AC~AD
AE~AF
B0~BF
C0~CF
D0~E0
E1
E2
E3
E4
E5~E7
E8
E9~EF
F0~FF
D7
1
1
1
1
1
1
1
1
1
D7
1
D6
0
0
0
0
1
1
1
1
1
D6
1
Rev 1.0
D5
1
1
1
1
0
1
1
1
1
D5
1
D4
0
0
0
1
0
0
0
0
0
D4
1
P 23/48 Dec 2003
1
S0
1
D3
D3
1
1
P3
0
0
0
X
D2
0
0
1
P2
X
0
0
1
0
D2
X
D1
0
1
1
P1
X
0
1
0
0
D1
X
D0
S0
1
D0
P0
X
1
0
0
0
D0
X
Set Power Save
Mode
Reserved
Start Internal
Oscillator
Reserved
Set Display
On/Off
Set Page Address
Set COM Output
Scan Direction
Reserved
Exit Power-save
Mode
Software Reset
Reserved
Exit N-line
Inversion
Reserved
Set Display Data
Length
Reserved
Extended
Features
Command
Reserved
Reserved
Set GDDRAM page address (0~10)
Reserved
Reserved
Reserved
Reserved
Description
S0=0: Standby mode (POR)
S0=1: Sleep mode
This command starts the internal
oscillator. Note that the oscillator is
OFF after reset, so this instruction must
be executed for initialization.
D0=0: Display OFF (POR)
D0=1: Display ON
using P3P2P1P0 for RAM access. The
page address is sets to 0 after reset.
S0=0: Normal mode (POR)
S0=1: Remapped mode. COM0 to
COM[N-1] becomes COM[N-1] to
COM0 when the duty is set to N. See
Figure 4 as an example for N equals to
80.
*Note: This command will not affect the
display of the icon lines
DC-DC converter, regulator and divider
status before entering the power-save
mode is restored. At POR, Power-save
Mode is released.
Initialize some internal registers
The frame will be inverted once per
frame
This command is valid only at 3-wire
SPI (PS0=PS1=L)
The second command specifies the
number of bytes of display data to be
written after this composite command.
D(7:0)=00: 1 byte of display data is to
be sent
D(7:0)=FF: 256 bytes of display data is
to be sent
Test mode commands and Extended
features, see Extended Command
Table.
Solomon Systech
www.DataSheet4U.com

Related parts for SSD1859