15.2.4.4 Freescale SPI Frame Format with SPO=0 and SPH=1
15.2.4.5 Freescale SPI Frame Format with SPO=1 and SPH=0
June 02, 2008
serial peripheral register and does not allow it to be altered if the SPH bit is logic zero. Therefore,
the master device must raise the SSIFss pin of the slave device between each data transfer to
enable the serial peripheral data write. On completion of the continuous transfer, the SSIFss pin
is returned to its idle state one SSIClk period after the last bit has been captured.
The transfer signal sequence for Freescale SPI format with SPO=0 and SPH=1 is shown in Figure
15-6 on page 425, which covers both single and continuous transfers.
Figure 15-6. Freescale SPI Frame Format with SPO=0 and SPH=1
SSIClk
SSIFss
Note:
In this configuration, during idle periods:
If the SSI is enabled and there is valid data within the transmit FIFO, the start of transmission is
signified by the SSIFss master signal being driven Low. The master SSITx output is enabled. After
a further one half SSIClk period, both master and slave valid data is enabled onto their respective
transmission lines. At the same time, the SSIClk is enabled with a rising edge transition.
Data is then captured on the falling edges and propagated on the rising edges of the SSIClk signal.
In the case of a single word transfer, after all bits have been transferred, the SSIFss line is returned
to its idle High state one SSIClk period after the last bit has been captured.
For continuous back-to-back transfers, the SSIFss pin is held Low between successive data words
and termination is the same as that of the single word transfer.
Single and continuous transmission signal sequences for Freescale SPI format with SPO=1 and
SPH=0 are shown in Figure 15-7 on page 426 and Figure 15-8 on page 426.
SSIRx
SSITx
SSIClk is forced Low
SSIFss is forced High
The transmit data line SSITx is arbitrarily forced Low
When the SSI is configured as a master, it enables the SSIClk pad
When the SSI is configured as a slave, it disables the SSIClk pad
Q is undefined.
Q
MSB
MSB
Preliminary
4 to 16 bits
LSB
LSB
LM3S3759 Microcontroller
Q
425