MT9079 Mitel Semiconductor, MT9079 Datasheet - Page 23

no-image

MT9079

Manufacturer Part Number
MT9079
Description
CMOS ST-BUS FAMILY Advanced Controller for E1
Manufacturer
Mitel Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MT9079AE
Manufacturer:
RFMD
Quantity:
7 198
Per Channel Receive Signalling (Page 6)
Page 06H, addresses 10001 to 11111 contain the
Receive Signalling Control Words for PCM 30
channels 1 to 15 and 16 to 30.
Serial per channel receive signalling status bits
appear on ST-BUS stream CSTo1. Table 16
describes the function of ST-BUS time slots 1 to 15,
and Table 17 describes the function of ST-BUS time
slots 17 to 31 of CSTo1.
Table 17 - Receive CAS Channels 17 to 31 (CSTo1)
Table 15 - Receive Channel Associated Signalling
Table 16 - Receive CAS Channels 1 to 15 (CSTo1)
7 - 4
3 - 0
7 - 4
3 - 0
7 - 4
3 - 0
Bit
Bit
Bit
A(n+15),
B(n+15),
A(n+15),
B(n+15),
C(n+15)
D(n+15)
C(n+15)
D(n+15)
Name
Name
Name
A(n),
B(n),
A(n),
B(n),
C(n)
D(n)
C(n)
D(n)
---
---
&
&
&
&
Receive Signalling Bits for Channel
n. These bits are received on the
PCM 30 2048 kbit/sec. link in bit
positions one to four of time slot 16 in
frame n (where n = 1 to 15), and are
the A, B, C, D signalling bits associ-
ated with channel n.
Receive Signalling Bits for Channel n
+ 15. These bits are received on the
PCM 30 2048 kbit/sec. link in bit
positions five to eight of time slot 16
in frame n (where n = 1 to 15), and
are the A, B, C, D signalling bits
associated with channel n + 15.
Receive Signalling Bits for Channel
n. These bits are received on the
PCM 30 2048 kbit/sec. link in bit
positions one to eight of time slot 16
in frame n (where n = 1 to 15), and
are the A, B, C, D signalling bits
associated with channel n.
Unused - high output level.
Receive Signalling Bits for Channel n
+ 15. These bits are received on the
PCM 30 2048 kbit/sec. link in bit
positions five to eight of time slot 16
in frame n (where n = 1 to 15), and
are the A, B, C, D signalling bits
associated with channel n + 15.
Unused - high output level.
(Page 6)
Functional Description
Functional Description
Functional Description
Per Time Slot Control Words (Pages 7 and 8)
The control functions described by Table 18 are
repeated for each ST-BUS time slot. When ST-BUS
access is selected, the programmed CSTi1 time slot
corresponds to the controlled ST-BUS or PCM 30
time slot. It should be noted that the two receive and
two transmit circular buffers are not accessible in
ST-BUS mode.
In processor and controller modes, pages 7 and 8
contain the 32 per time slot control words. Page 7
addresses 10000 to 11111 correspond to time slots 0
to 15, while page 8 addresses 10000 to 11111
correspond to time slots 16 to 31. These control bits
are not cleared by the RESET or RST reset
functions.
Bit
7
6
5
4
Table 18 - Per Time Slot Control Words
CDDTC
Name
RTSL
CDIN
LTSL
(Pages 7 and 8) (continued)
Code Insert Activation. If one, the
data of CIW7-0 is transmitted in the
corresponding PCM 30 time slot. If
zero, the data on DSTi is transmitted
on the corresponding PCM 30 time
slot.
Code Detect Activation. If one, the
data received on the corresponding
PCM 30 time slot is compared with
the unmasked bits of the code detect
word. When the DATA interrupt is
unmasked and this positive match is
made, an interrupt will be initiated. If
zero, the data is not be compared to
the unmasked bits of the code detect
word.
Remote Time Slot Loopback. If one,
the corresponding PCM 30 receive
time slot is looped to the correspond-
ing PCM 30 transmit time slot. This
received time slot will also be present
on DSTo. An ST-BUS offset may
force a single frame delay. If zero, the
loopback is disabled.
Local Time Slot Loopback. If one, the
corresponding transmit time slot is
looped to the corresponding receive
time slot. This transmit time slot will
also be present on the transmit PCM
30 stream. An ST-BUS offset may
force a single frame delay. If zero,
this loopback is disabled.
Functional Description
MT9079
4-259

Related parts for MT9079