The TE control bit sets the state of the transmit
E-bits when the receive side has lost CRC-4
synchronization. In this case if the interface is the
Terminal Equipment (TE) side, then the E-bits must
be zero. If the interface is the Network Termination
(NT) side, the transmit E-bits must be one when
CRC-4 synchronization is lost.
synchronization is achieved the transmit E-bits will
function according to ITU-T G.704.
The MT9079 has a suite of 30 maskable interrupts.
At this point in the initialization procedure the SYNI,
RAII, AISI, AIS16I, LOSI, FERI, BPVO and SLPI
interrupts will be unmasked and all others will be
masked.
interrupts, the SPND control bit should be kept at
one.
Power-on Reset - RESET
supply rise time
Select mode of operation.
Note 1.
input = RC > = 5 x power
Write 00H to all control
registers of pages 7 & 8
Select National bit, data
link, and AIS mode of
operation. Note 1.
8KSEL bit = 1 if using the
E8Ko output for loop
(slave) timing. Note 1.
TAIS input = low
If
SPND bit = 1
the
START
A
application
does
Figure 12 - MT9079 Initialization Procedure
When CRC-4
not
Read interrupt vector
register, page 4. Note 3.
Select PCM 30 line
encoding. Note 1.
Clear the error counters
of page 4. Note 2.
Select ST-BUS offset.
Note 1.
Mask and unmask
interrupts. Note 1.
TAIS input = high
require
SPND = 0.
Note 3.
is Interface
STOP
TE?
A
NO
Adjusting the ST-BUS offset will move the bit
positions of the ST-BUS output streams with respect
to the input frame pulse F0i. This can be used to
compensate for large delays in very long backplane
applications. It can also be used to minimize the
delay through the receive elastic buffer.
Selection of the PCM 30 encoding will be determined
by the line interface arrangement used. The default
is HDB3 encoding on bipolar non-return to zero
signals, which will interface directly to most Line
Interface Units (LIU).
After a power-on reset the state of the error counters
of page 4 will be undetermined. Therefore, each of
the counters appropriate to the application should be
cleared by writing a zero value to the counter
YES
TE bit = 1
Notes:
1. Skip if default option is required.
2. Skip if counters are not used.
3. Skip if interrupts are not used.