Datasheet - D e t a i l e d D e s c r i p t i o n
Table 33. Control Registers
www.austriamicrosystems.com/AS8510
Digital Control Registers
Addr in
HEX
08
09
(Reset Control Register)
(Clock Control Register)
Register Name
RESET_REG
CLK_REG
POR Value
0010_0000
1100_0000
R/W
R/W
R/W
Revision 3.4
D[7:6]
D[5:4]
D[3:2]
D[5:0]
D[1]
D[0]
D[7]
D[6]
register bit. This bit will take a default 1 value on coming
Measurement Path can be soft reset by writing “0” into
this register bit. This bit will take a default 1 value after
These two bits select the division ratio of HS clock, by
Oversampling frequency clock selection. Default is 00
which it should be divided before providing it on CLK
Entire device can be soft reset by writing “0” into this
These two bits select the division ratio for HS clock/
00
01
10
00
01
10
11
00
01
10
11
0
1
This bit selects the division ratio of LS clock
external clock. Default is 10 (division by 4)
8-bit Control / Status Data
(high speed (HS) internal Clock)
pin. Default is 00 (No Division)
Internal HS Clock with No Clock Output
Measurement Path is reset.
LS _CLK undivided (Low Speed clock)
Internal HS Clock with Clock Output
out of Reset
Reserved
Reserved
LS _CLK divide by 2
External Clock
No Division
No division
Divide by 2
Divide by 4
Divide by 8
Divide by 2
Divide by 4
Divide by 8
31 - 46