ep2c35 Altera Corporation, ep2c35 Datasheet - Page 146
ep2c35
Manufacturer Part Number
ep2c35
Description
Cyclone Ii Device Family Data Sheet
Manufacturer
Altera Corporation
Datasheet
1.EP2C35.pdf
(168 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
ep2c35F484
Manufacturer:
ALTERA
Quantity:
1 235
Company:
Part Number:
ep2c35F484C6N
Manufacturer:
ALTERA
Quantity:
591
Part Number:
ep2c35F484C6N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Company:
Part Number:
ep2c35F484C7
Manufacturer:
ALTERA
Quantity:
300
Part Number:
ep2c35F484C7
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Company:
Part Number:
ep2c35F484C7ES
Manufacturer:
OKI
Quantity:
45 725
Part Number:
ep2c35F484C7ES
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Company:
Part Number:
ep2c35F484C7N
Manufacturer:
ALTERA
Quantity:
465
Timing Specifications
Figure 5–3. High-Speed I/O Timing Diagram
5–56
Cyclone II Device Handbook, Volume 1
Sampling window
Receiver input skew
margin
Input jitter (peak to peak)
Output jitter (peak to peak)
Signal rise time
Signal fall time
Lock time
Table 5–47. High-Speed I/O Timing Definitions (Part 2 of 2)
Parameter
Internal Clock
Input Clock
Input Data
Receiver
External
SW
RSKM
t
t
t
R I S E
FA L L
L O C K
Symbol
Figure 5–4
TCCS
—
—
The period of time during which the data must be valid in order for you
to capture it correctly. Sampling window is the sum of the setup time,
hold time, and jitter. The window of t
in the sampling window.
SW = TUI – TCCS – (2 × RSKM)
RSKM is defined by the total margin left after accounting for the
sampling window and TCCS.
RSKM = (TUI – SW – TCCS) / 2
Peak-to-peak input jitter on high-speed PLLs.
Peak-to-peak output jitter on high-speed PLLs.
Low-to-high transmission time.
High-to-low transmission time.
Lock time for high-speed transmitter and receiver PLLs.
RSKM
shows the high-speed I/O timing budget.
Sampling Window (SW)
Time Unit Interval (TUI)
Description
SU
RSKM
+ t
H
is expected to be centered
TCCS
Altera Corporation