ep2c35 Altera Corporation, ep2c35 Datasheet - Page 156

no-image

ep2c35

Manufacturer Part Number
ep2c35
Description
Cyclone Ii Device Family Data Sheet
Manufacturer
Altera Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ep2c35F484
Manufacturer:
ALTERA
Quantity:
1 235
Part Number:
ep2c35F484
Manufacturer:
ALTERA
0
Part Number:
ep2c35F48418NK
Manufacturer:
ALTERA
0
Part Number:
ep2c35F484C6
Manufacturer:
Altera
Quantity:
10 000
Part Number:
ep2c35F484C6
Manufacturer:
ALTERA
0
Part Number:
ep2c35F484C6N
Manufacturer:
ALTERA
Quantity:
591
Part Number:
ep2c35F484C6N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
ep2c35F484C6N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Company:
Part Number:
ep2c35F484C6N
Quantity:
1 000
Part Number:
ep2c35F484C7
Manufacturer:
ALTERA
Quantity:
300
Part Number:
ep2c35F484C7
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
ep2c35F484C7ES
Manufacturer:
OKI
Quantity:
45 725
Part Number:
ep2c35F484C7ES
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
ep2c35F484C7N
Manufacturer:
ALTERA
Quantity:
465
Timing Specifications
5–66
Cyclone II Device Handbook, Volume 1
f
f
f
t
f
clock output)
f
t
t
t
t
I N
I N P F D
I N D U T Y
I N J I T T E R
O U T _ E X T
O U T
O U T D U T Y
J I T T E R
L O C K
PLL_PSERR
Table 5–54. PLL Specifications
(to global clock)
(p-p)
Symbol
(5)
(external
(2)
Input clock frequency (–6 speed grade)
Input clock frequency (–7 speed grade)
Input clock frequency (–8 speed grade)
PFD input frequency (–6 speed grade)
PFD input frequency (–7 speed grade)
PFD input frequency (–8 speed grade)
Input clock duty cycle
Input clock period jitter
PLL output frequency (–6 speed grade)
PLL output frequency (–7 speed grade)
PLL output frequency (–8 speed grade)
PLL output frequency (–6 speed grade)
PLL output frequency (–7 speed grade)
PLL output frequency (–8 speed grade)
Duty cycle for external clock output (when
set to 50%)
Period jitter for external clock output
f
f
Time required to lock from end of device
configuration
Accuracy of PLL phase shift
O U T _ E X T
O U T _ E X T
PLL Timing Specifications
Table 5–54
the commercial junction temperature range (0° to 85° C), the industrial
junction temperature range (–40° to 100° C), the automotive junction
temperature range (–40° to 125° C), and the extended temperature range
(–40° to 125° C). Follow the PLL specifications for –8 speed grade devices
when operating in the industrial, automotive, or extended temperature
range.
Note (1)
> 100 MHz
≤ 100 MHz
Parameter
describes the Cyclone II PLL specifications when operating in
(Part 1 of 2)
Min
10
10
10
10
10
10
40
10
10
10
10
10
10
45
200
Typ
Altera Corporation
100
402.5
402.5
402.5
402.5
Max
500
450
±60
300
(4)
(4)
(4)
60
(4)
(4)
(4)
55
30
February 2008
(6)
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
Unit
mUI
ps
ps
μs
ps
%
%