dp83846a National Semiconductor Corporation, dp83846a Datasheet - Page 36

no-image

dp83846a

Manufacturer Part Number
dp83846a
Description
Dsphyter ? Single 10/100 Ethernet Transceiver
Manufacturer
National Semiconductor Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DP83846A
Quantity:
5
Part Number:
DP83846A
Quantity:
4 383
Part Number:
dp83846aVHCA4
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
dp83846aVHG
Manufacturer:
NSC
Quantity:
516
Part Number:
dp83846aVHG
Manufacturer:
NS
Quantity:
885
Part Number:
dp83846aVHG
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
dp83846aVHG
Manufacturer:
NS
Quantity:
1 000
Part Number:
dp83846aVHG
Manufacturer:
NSC
Quantity:
8 000
Part Number:
dp83846aVHG
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
dp83846aVHG-LQFP80
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
dp83846aVHG/NOPB
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
dp83846aVHG/NOPB
Manufacturer:
NS/国半
Quantity:
20 000
This register contains the next page information sent by this device to its Link Partner during Auto-Negotiation.
10:0
Bit
15
14
13
12
11
Table 15. Auto-Negotiation Next Page Transmit Register (ANNPTR), address 0x07
RESERVED
Bit Name
TOG_TX
CODE
ACK2
MP
NP
<000 0000 0001>,
Default
0, RW
1, RW
0, RW
0, RO
0, RO
RW
Next Page Indication:
0 = No other Next Page Transfer desired.
1 = Another Next Page desired.
RESERVED: Writes ignored, read as 0.
Message Page:
1 = Message Page.
0 = Unformatted Page.
Acknowledge2:
1 = Will comply with message.
0 = Cannot comply with message.
Acknowledge2 is used by the next page function to indicate that Lo-
cal Device has the ability to comply with the message received.
Toggle:
1 = Value of toggle bit in previously transmitted Link Code Word
was 0.
0 = Value of toggle bit in previously transmitted Link Code Word
was 1.
Toggle is used by the Arbitration function within Auto-Negotiation
to ensure synchronization with the Link Partner during Next Page
exchange. This bit shall always take the opposite value of the Tog-
gle bit in the previously exchanged Link Code Word.
This field represents the code field of the next page transmission.
If the MP bit is set (bit 13 of this register), then the code shall be
interpreted as a "Message Page”, as defined in annex 28C of IEEE
802.3u. Otherwise, the code shall be interpreted as an "Unformat-
ted Page”, and the interpretation is application specific.
The default value of the CODE represents a Null Page as defined
in Annex 28C of IEEE 802.3u.
36
Description
www.national.com

Related parts for dp83846a