ATA6602/ATA6603
C. Load Data Low Byte
D. Load Data High Byte
E. Latch Data
F. Repeat B through E until the entire buffer is filled or until all data within the page is loaded.
While the lower bits in the address are mapped to words within the page, the higher bits address
the pages within the FLASH. This is illustrated in
than eight bits are required to address words in the page (pagesize < 256), the most significant
bit(s) in the address low byte are used to address the page when performing a Page Write.
G. Load Address High byte
H. Program Page
I. Repeat B through H until the entire Flash is programmed or until all data has been
programmed.
J. End Page Programming
1. Set XA1, XA0 to “01”. This enables data loading.
2. Set DATA = Data low byte (0x00 - 0xFF).
3. Give XTAL1 a positive pulse. This loads the data byte.
1. Set BS1 to “1”. This selects high data byte.
2. Set XA1, XA0 to “01”. This enables data loading.
3. Set DATA = Data high byte (0x00 - 0xFF).
4. Give XTAL1 a positive pulse. This loads the data byte.
1. Set BS1 to “1”. This selects high data byte.
2. Give PAGEL a positive pulse. This latches the data bytes (see
1. Set XA1, XA0 to “00”. This enables address loading.
2. Set BS1 to “1”. This selects high address.
3. Set DATA = Address high byte (0x00 - 0xFF).
4. Give XTAL1 a positive pulse. This loads the address high byte.
1. Give WR a negative pulse. This starts programming of the entire page of data.
2. Wait until RDY/BSY goes high (see
1. 1. Set XA1, XA0 to “10”. This enables command loading.
2. Set DATA to “0000 0000”. This is the command for No Operation.
3. Give XTAL1 a positive pulse. This loads the command, and the internal write signals
307
RDY/BSY goes low.
are reset.
for signal waveforms).
Figure 4-119 on page 307
Figure 4-118 on page
for signal waveforms).
Figure 4-119 on page
307. Note that if less
4921D–AUTO–08/07

Related parts for ata6603