at25dq321a ATMEL Corporation, at25dq321a Datasheet - Page 31

no-image

at25dq321a

Manufacturer Part Number
at25dq321a
Description
32-megabit 2.7-volt Minimum Spi Serial Flash Memory With Dual-i/o And Quad-i/o Support
Manufacturer
ATMEL Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
at25dq321a-MH-T
Manufacturer:
NUMONYX
Quantity:
2 600
8718A–DFLASH–04/10
10.
10.1
Security Commands
Sector Lockdown
Certain applications require that portions of the Flash memory array be permanently protected against malicious
attempts at altering program code, data modules, security information, or encryption/decryption algorithms, keys,
and routines. To address these applications, the device incorporates a sector lockdown mechanism that allows any
combination of individual 64-Kbyte sectors to be permanently locked so that they become read only. Once a sector
is locked down, it can never be erased or programmed again, and it can never be unlocked from the locked down
state.
Each 64-Kbyte physical sector has a corresponding single-bit Sector Lockdown Register that is used to control the
lockdown status of that sector. These registers are nonvolatile and will retain their state even after a device power-
cycle or reset operation. The following table outlines the two states of the Sector Lockdown Registers.
Table 10-1.
Issuing the Sector Lockdown command to a particular sector address will set the corresponding Sector Lockdown
Register to the logical “1” state. Each Sector Lockdown Register can only be set once; therefore, once set to the
logical “1” state, a Sector Lockdown Register cannot be reset back to the logical “0” state.
Before the Sector Lockdown command can be issued, the Write Enable command must have been previously
issued to set the WEL bit in the Status Register to a logical “1”. In addition, the Sector Lockdown Enabled (SLE) bit
in the Status Register must have also been previously set to the logical “1” state by using the Write Status Register
Byte 2 command (see
CS pin must first be asserted and the opcode of 33h must be clocked into the device followed by three address
bytes designating any address within the 64-Kbyte sector to be locked down. After the three address bytes have
been clocked in, a confirmation byte of D0h must also be clocked in immediately following the three address bytes.
Any additional data clocked into the device after the first byte of data will be ignored. When the CS pin is
deasserted, the Sector Lockdown Register corresponding to the sector addressed by A23-A0 will be set to the
logical “1” state, and the sector itself will then be permanently locked down from program and erase operations
within a time of t
The complete three address bytes and the correct confirmation byte value of D0h must be clocked into the device
before the CS pin is deasserted, and the CS pin must be deasserted on a byte boundary (multiples of eight bits);
otherwise, the device will abort the operation. When the device aborts the Sector Lockdown operation, the state of
the corresponding Sector Lockdown Register as well as the SLE bit in the Status Register will be unchanged;
however, the WEL bit in the Status Register will be reset to a logical “0”.
As a safeguard against accidental or erroneous locking down of sectors, the Sector Lockdown command can be
enabled and disabled as needed by using the SLE bit in the Status Register. In addition, the current sector
lockdown state can be frozen so that no further modifications to the Sector Lockdown Registers can be made (see
“Freeze Sector Lockdown State”
state is frozen, then any attempts to issue the Sector Lockdown command will be ignored, and the device will reset
the WEL bit in the Status Register back to a logical “0” and return to the idle state once the CS pin has been
deasserted.
Value
0
1
Sector Lockdown Status
Sector is not locked down and can be programmed and erased. This is the default state.
Sector is permanently locked down and can never be programmed or erased again.
Sector Lockdown Register Values
LOCK
. In addition, the WEL bit in the Status Register will be reset back to the logical “0” state.
“Write Status Register Byte 2” on page
below). If the Sector Lockdown command is disabled or if the sector lockdown
AT25DQ321A [Preliminary]
41). To issue the Sector Lockdown command, the
31