STANDARD PMBus COMMANDS
OPERATION (01h)
The OPERATION command is a standard PMBus command
that controls the MOSFET switch. This command may be
used to switch the MOSFET ON and OFF under host control.
It is also used to re-enable the MOSFET after a fault triggered
shutdown. Writing an OFF command, followed by an ON
command, will clear all faults and re-enable the device. Writ-
ing only an ON after a fault-triggered shutdown will not clear
the fault registers or re-enable the device. The OPERATION
command is issued with the write byte protocol.
CLEAR FAULTS (03h)
The CLEAR_FAULTS command is a standard PMBus com-
mand that resets all stored warning and fault flags and the
SMBA signal. If a fault or warning condition still exists when
the CLEAR_FAULTS command is issued, the SMBA signal
may not clear or will re-assert almost immediately. Issuing a
CLEAR_FAULTS command will not cause the MOSFET to
switch back on in the event of a fault turnoff - that must be
done by issuing an OPERATION command after the fault
condition is cleared. This command uses the PMBus send
byte protocol.
CAPABILITY (19h)
The CAPABILITY command is a standard PMBus command
that returns information about the PMBus functions supported
by the LM5066. This command is read with the PMBus read
byte protocol.
VOUT_UV_WARN_LIMIT (58h)
The VOUT_UV_WARN_LIMIT command is a standard PM-
Bus command that allows configuring or reading the threshold
for the VOUT Under-voltage Warning detection. Reading and
writing to this register should use the coefficients shown in the
Telemetry and Warning Conversion Coefficients Table. Ac-
cesses to this command should use the PMBus read or write
word protocol. If the measured value of VOUT falls below the
value in this register, VOUT UV Warn flags are set and the
SMBA signal is asserted.
Value
80h
00h
Value
B0h
TABLE 2. Recognized OPERATION Command Values
TABLE 3. CAPABILITY Register
Meaning
Switch ON
Switch OFF
Meaning
Supports Packet
Error Check,
400Kbits/sec,
Supports SMBus
Alert
Default
80h
n/a
Default
B0h
29
OT_FAULT_LIMIT (4Fh)
The OT_FAULT_LIMIT command is a standard PMBus com-
mand that allows configuring or reading the threshold for the
overtemperature fault detection. Reading and writing to this
register should use the coefficients shown in the Telemetry
and Warning Conversion Coefficients Table. Accesses to this
command should use the PMBus read or write word protocol.
If the measured temperature exceeds this value, an overtem-
perature fault is triggered and the MOSFET is switched off,
OT FAULT flags set, and the SMBA signal asserted. After the
measured temperature falls below the value in this register,
the MOSFET may be switched back on with the OPERATION
command. A single temperature measurement is an average
of 16 round-robin cycles; therefore, the minimum temperature
fault detection time is 16 ms.
OT_WARN_LIMIT (51h)
The OT_WARN_LIMIT command is a standard PMBus com-
mand that allows configuring or reading the threshold for the
overtemperature warning detection. Reading and writing to
this register should use the coefficients shown in the Teleme-
try and Warning Conversion Coefficients Table. Accesses to
this command should use the PMBus read or write word pro-
tocol. If the measured temperature exceeds this value, an
Overtemperature warning is triggered and the OT WARN
flags set in the respective registers and the SMBA signal as-
serted. A single temperature measurement is an average of
16 round-robin cycles; therefore, the minimum temperature
warn detection time is 16 ms.
VIN_OV_WARN_LIMIT (57h)
Value
1h – 0FFFh
0000h
Value
0h – 0FFEh
0FFFh
Value
0h – 0FFEh
0FFFh
TABLE 4. VOUT_UV_WARN_LIMIT Register
TABLE 5. OT_FAULT_LIMIT Register
TABLE 6. OT_WARN_LIMIT Register
Meaning
VOUT Under-
voltage Warning
detection
threshold
VOUT Under-
voltage Warning
disabled
Meaning
Overtemperature
Fault threshold
value
Overtemperature
Fault detection
disabled
Meaning
Overtemperature
Warn Threshold
Value
Overtemperature
Warn detection
disabled
Default
0000h (disabled)
n/a
Default
0960h (150°C)
n/a
Default
07D0h (125°C)
n/a