stm1001t STMicroelectronics, stm1001t Datasheet - Page 8

no-image

stm1001t

Manufacturer Part Number
stm1001t
Description
Reset Circuit
Manufacturer
STMicroelectronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STM1001T
Manufacturer:
ST
0
Part Number:
STM1001T
Manufacturer:
ST
Quantity:
20 000
Part Number:
stm1001tWX6
Manufacturer:
ST
0
Part Number:
stm1001tWX6F
Manufacturer:
STMicroelectronics
Quantity:
38 287
Part Number:
stm1001tWX6F
Manufacturer:
STM
Quantity:
2
Part Number:
stm1001tWX6F
Manufacturer:
ST
0
Part Number:
stm1001tWX6F
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
stm1001tWX6F
Quantity:
1 883
Part Number:
stm1001tWX6F���ֻ� ��
Manufacturer:
ST
0
STM1001
MAXIMUM RATING
Stressing the device above the rating listed in the
Absolute Maximum Ratings” table may cause per-
manent damage to the device. These are stress
ratings only and operation of the device at these or
any other conditions above those indicated in the
Operating sections of this specification is not im-
Table 2. Absolute Maximum Ratings
Note: 1. Reflow at peak temperature of 255°C to 260°C for < 30 seconds (total thermal budget not to exceed 180°C for between 90 to 150
DC AND AC PARAMETERS
This section summarizes the operating measure-
ment conditions, and the DC and AC characteris-
tics of the device. The parameters in the DC and
AC characteristics Tables that follow, are derived
from tests performed under the Measurement
Table 3. Operating and AC Measurement Conditions
Figure 12. AC Testing Input/Output Waveforms
8/14
V
Ambient Operating Temperature (T
Input Rise and Fall Times
Input Pulse Voltages
Input and Output Timing Ref. Voltages
0.8V CC
0.2V CC
CC
Symbol
T
T
Supply Voltage
SLD
V
V
P
STG
I
seconds).
CC
O
IO
D
(1)
Storage Temperature (V
Lead Solder Temperature for 10 seconds
Input or Output Voltage
Supply Voltage
Output Current
Power Dissipation
Parameter
A
)
CC
Parameter
Off)
0.7V CC
0.3V CC
AI02568
plied. Exposure to Absolute Maximum Rating con-
ditions for extended periods may affect device
reliability. Refer also to the STMicroelectronics
SURE Program and other relevant quality docu-
ments.
Conditions summarized in Table 3, Operating and
AC Measurement Conditions. Designers should
check that the operating conditions in their circuit
match the operating conditions when relying on
the quoted parameters.
0.2 to 0.8V
0.3 to 0.7V
STM1001
1.0 to 5.5
–40 to 85
5
–0.3 to V
–55 to 150
–0.3 to 7.0
CC
CC
Value
260
320
20
CC
+0.3
Unit
°C
ns
Unit
mW
V
V
V
mA
°C
°C
V
V

Related parts for stm1001t