sc16c852sviet NXP Semiconductors, sc16c852sviet Datasheet - Page 33

no-image

sc16c852sviet

Manufacturer Part Number
sc16c852sviet
Description
1.8 V Dual Uart, 20 Mbit/s Max. With 128-byte Fifos, Infrared Irda , And Xscale Vlio Bus Interface
Manufacturer
NXP Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SC16C852SVIET
Manufacturer:
NXP
Quantity:
385
Part Number:
SC16C852SVIET
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
sc16c852sviet,115
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
sc16c852sviet,151
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
sc16c852sviet,157
Manufacturer:
NXP Semiconductors
Quantity:
10 000
NXP Semiconductors
SC16C852SV_1
Product data sheet
7.17 Flow Control Trigger Level High (FLWCNTH)
7.18 Flow Control Trigger Level Low (FLWCNTL)
7.19 Clock Prescaler (CLKPRES)
This 8-bit register is used to store the receive FIFO high threshold levels to start/stop
transmission during hardware/software flow control.
register bit settings; see
Table 27.
[1]
This 8-bit register is used to store the receive FIFO low threshold levels to start/stop
transmission during hardware/software flow control.
register bit settings; see
Table 28.
[1]
This register hold values for the clock prescaler.
Table 29.
Bit
7:0
Bit
7:0
Bit
7:4
3:0
For 32-byte FIFO mode, refer to
For 32-byte FIFO mode, refer to
Symbol
FLWCNTH[7:0]
Symbol
FLWCNTL[7:0]
Symbol
CLKPRES[7:4]
CLKPRES[3:0]
FLWCNTH register bits description
FLWCNTL register bits description
Clock Prescaler register description
Dual UART with 128-byte FIFOs, IrDA, and XScale VLIO bus interface
Rev. 01 — 23 September 2008
Section
Section
Description
This register stores the programmable HIGH threshold level for
hardware and software flow control for 128-byte FIFO mode.
Description
This register stores the programmable LOW threshold level for
hardware and software flow control for 128-byte FIFO mode.
Description
reserved
clock prescaler value; reset to 0
0x00 = trigger level is set to 1
0x01 = trigger level is set to 1
...
0x80 = trigger level is set to 128
0x00 = trigger level is set to 1
0x01 = trigger level is set to 1
...
0x80 = trigger level is set to 128
Section 7.3 “FIFO Control Register
Section 7.3 “FIFO Control Register
6.5.
6.5.
Table 27
Table 28
(FCR)”.
(FCR)”.
SC16C852SV
shows transmission control
shows transmission control
© NXP B.V. 2008. All rights reserved.
[1]
[1]
33 of 48