adum3210 Analog Devices, Inc., adum3210 Datasheet - Page 10

no-image

adum3210

Manufacturer Part Number
adum3210
Description
Dual-channel Digital Isolator, Enhanced System-level Esd Reliability
Manufacturer
Analog Devices, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
adum3210ARZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adum3210ARZ-RL7
Manufacturer:
TI
Quantity:
15 000
Part Number:
adum3210BRZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adum3210TRZ
Manufacturer:
ADI
Quantity:
28
Part Number:
adum3210TRZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
adum3210TRZ
Quantity:
20 000
Part Number:
adum3210WARZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ADuM3210
PACKAGE CHARACTERISTICS
Table 6.
Parameter
Resistance (Input-to-Output)
Capacitance (Input-to-Output)
Input Capacitance
IC Junction-to-Case Thermal Resistance, Side 1
IC Junction-to-Case Thermal Resistance, Side 2
1
REGULATORY INFORMATION
The ADuM3210 is approved by the organizations listed in Table 7.
Table 7.
UL
Recognized under UL 1577
Component Recognition
Program
Single/Basic 2500 V rms
Isolation Voltage
File E214100
1
2
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 8.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
The device is considered a 2-terminal device; Pin 1 through Pin 4 are shorted together, and Pin 5 through Pin 8 are shorted together.
In accordance with UL 1577, each ADuM3210 is proof tested by applying an insulation test voltage ≥ 3000 V rms for 1 second (current leakage detection limit = 5 μA).
In accordance with DIN V VDE V 0884-10, each ADuM3210 is proof tested by applying an insulation test voltage ≥ 1050 V peak for 1 second (partial discharge detection
limit = 5 pC). An asterisk (*) marking branded on the component designates DIN V VDE V 0884-10 approval.
1
1
1
CSA
Approved under CSA Component Acceptance Notice #5A
Basic insulation per CSA 60950-1-03 and IEC 60950-1,
400 V rms (566 V peak) maximum working voltage
Functional insulation per CSA 60950-1-03 and IEC 60950-1,
800 V rms(1131 V peak) maximum working voltage
File 205078
Symbol
L(I01)
L(I02)
CTI
Symbol
R
C
C
θ
θ
I-O
JCI
JCO
I-O
I
Rev. A | Page 10 of 20
Value
2500
4.90 min
4.01 min
0.017 min
>175
IIIa
Min
Typ
10
1.0
4.0
46
41
Unit
V rms
mm
mm
mm
V
12
Max
Conditions
1-minute duration
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Insulation distance through insulation
Material Group (DIN VDE 0110, 1/89, Table 1)
DIN IEC 112/VDE 0303 Part 1
Unit
Ω
pF
pF
°C/W
°C/W
VDE
Certified according to DIN V VDE V 0884-10
(VDE V 0884-10): 2006-12
Reinforced insulation, 560 V peak
File 2471900-4880-0001
Test Conditions
f = 1 MHz
Thermocouple located at center
of package underside
2