afct-57d5anpz Avago Technologies, afct-57d5anpz Datasheet - Page 5
afct-57d5anpz
Manufacturer Part Number
afct-57d5anpz
Description
Digital Diagnostic Sfp Small Form Pluggable , Low Voltage 3.3 V 25km, 1310nm Dfb, 8.5/4.25/2.125 Gbd Fibre Channel Rohs Compliant Digital Diagnostic Optical Transceiver
Manufacturer
Avago Technologies
Datasheet
1.AFCT-57D5ANPZ.pdf
(18 pages)
Electromagnetic Interference (EMI)
Equipment incorporating gigabit transceivers is typically
subject to regulation by the FCC in the United States,
CENELEC EN55022 (CISPR 22) in Europe and VCCI in Japan.
The AFCT-57D5ANPZ’s compliance to these standards is
detailed in Table 1. The metal housing and shielded design
of the AFCT-57D5ANPZ minimizes the EMI challenge facing
the equipment designer.
Table 1. Regulatory Compliance
Feature
Electrostatic Discharge (ESD)
to the Electrical Pins
Electrostatic Discharge (ESD)
to the Duplex LC Receptacle
Electrostatic Discharge (ESD)
to the Optical Connector
Electromagnetic Interference
(EMI)
Immunity
Laser Eye Safety and
Equipment Type Testing
Component Recognition
RoHS Compliance
5
Product Safety
Rheinland
TUV
¬
APPROVED
GEPRUFT
BAUART
TYPE
¬
Test Method
MIL-STD-883C
Method 3015.4
Variation of IEC 61000-4-2
GR1089
Variation of IEC 801-2
FCC Class B
CENELEC EN55022 Class B
(CISPR 22A)
VCCI Class 1
Variation of IEC 61000-4-3
US FDA CDRH AEL Class 1
US21 CFR, Subchapter J per
Paragraphs 1002.10
and 1002.12
(IEC) EN60825-1: 1994 + A11 + A2
(IEC) EN60825-2: 1994 + A1
(IEC) EN60950: 1992 + A1 + A2 +
A3 + A4 + A11
Underwriters Laboratories and
Canadian Standards Association
Joint Component Recognition
for Information Technology
Equipment including Electrical
Business Equipment
EMI Immunity (Susceptibility)
Due to its shielded design, the EMI immunity of the AFCT-
57D5ANPZ exceeds typical industry standards.
Flammability
The AFCT-57D5ANPZ optical transceiver is made of metal
and high strength, heat resistant, chemical resistant and
UL 94V-0 flame retardant plastic.
Performance
Class 1 (> 2000 Volts)
Typically, no damage occurs with 25 kV when
the duplex LC connector receptacle is
contacted by a Human Body Model probe.
10 contacts of 8 kV on the electrical faceplate
with device inserted into a panel.
Air discharge of 15 kV (min.) contact to
connector without damage.
System margins are dependent on customer
board and chassis design.
Typically shows no measurable effect from a
10 V/m field swept from 10 MHz to 1 GHz.
CDRH certification TBD
TUV file TBD
UL file TBD
Less than 1000 ppm of cadmium, lead, mercury,
hexavalent chromium, polybrominated biphenyls,
and polybrominated biphenyl ethers.