Datasheet
Table 2. Pin Description
Pin
1 
2 
3 
4 
5 
6 
7 
8 
9 
10 
11 
12 
13 
14 
15 
16 
17 
18 
19 
20 
Notes:
1.  TX_FAULT is an open collector/drain output, which must be pulled up with a 4.7 k – 10 kΩ resistor on the host board. When high, this output indi-
2.  TX_DISABLE is an input that is used to shut down the transmitter optical output. It is internally pulled up (within the transceiver) with a 6.8 kΩ 
3.  The signals Mod-Def 0, 1, 2 designate the two wire serial interface pins. They must be pulled up with a 4.7 k – 10 kΩ resistor on the host board. 
4. RX_LOS (Rx Loss of Signal) is an open collector/drain output that must be pulled up with a 4.7 k – 10 kΩ resistor on the host board. When high, this 
5.  RD-/+ designate the differential receiver outputs. They are AC coupled 100 Ω differential lines which should be terminated with 100 Ω differential 
6.  VccR and VccT are the receiver and transmitter power supplies. They are defined at the SFP connector pin. The maximum supply current is 300 mA 
7.  TD-/+ designate the differential transmitter inputs. They are AC coupled differential lines with 100 Ω differential termination inside the module. 
7
cates a laser fault of some kind. Low indicates normal operation. In the low state, the output will be pulled to < 0.8  V .
resistor.
Mod-Def 0 is grounded by the module to indicate the module is present
Mod-Def 1 is serial clock line (SCL) of two wire serial interface 
Mod-Def 2 is serial data line (SDA) of two wire serial interface 
output indicates the received optical power is below the worst case receiver sensitivity (as defined by the standard in use). Low indicates normal 
operation. In the low state, the output will be pulled to < 0.8  V .
at the host SERDES input. AC coupling is done inside the transceiver and is not required on the host board. The voltage swing on these lines will 
be between 370 and 850 mV differential (185 - 425 mV single ended) when properly terminated.
and the associated in-rush current will typically be no more than 30 mA above steady state after 2 microseconds.
The AC coupling is done inside the module and is not required on the host board. The inputs will accept differential swings of 180 - 1200 mV (90 
- 600 mV single ended)
Low (0 – 0.8  V ): 
Between (0.8  V  and 2.0  V ): 
High (2.0 – Vcc max) or OPEN: 
Name
VeeT 
TX_FAULT 
TX_DISABLE 
MOD-DEF2 
MOD-DEF1 
MOD-DEF0 
No Connect 
RX_LOS 
No Connect 
VeeR 
VeeR 
RD- 
RD+ 
VeeR 
VccR 
VccT 
VeeT 
TD+ 
TD- 
VeeT 
Function/Description
Transmitter Ground
Transmitter Fault Indication – High indicates a fault condition 
Transmitter Disable  –  Module electrical input disables on high or open 
Module Definition 2 – Two wire serial ID interface data line (SDA) 
Module Definition 1 – Two wire serial ID interface clock line (SCL) 
Module Definition 0 – Grounded in module (module present indicator) 
Internal pull up 30K Ω to VCC 
Loss of Signal – High indicates loss of received optical signal 
Internal pull up 30K Ω to VCC
Receiver Ground
Receiver Ground
Inverse Received Data Out 
Received Data Out 
Receiver Ground
Receiver Power  + 3.3 V 
Transmitter Power  +  3.3 V 
Transmitter Ground
Transmitter Data In 
Inverse Transmitter Data In 
Transmitter Ground
Transmitter on
Undefined
Transmitter Disabled
Notes
Note 1
Note 2
Note 3
Note 3
Note 3
Note 4
Note 5
Note 5
Note 6
Note 6
Note 7
Note 7