1
EDGES[1:0]
Bits 6- 5 - RANGE[1:0] - Adjusts the range of reported and programmed tachometer reading values.
The RANGE bits determine the weighting of all TACH values (including the Valid TACH Count, TACH
Target, and TACH reading) as shown in
Bits 4-3 - EDGES[1:0] - determines the minimum number of edges that must be detected on the
TACHx signal to determine a single rotation. A typical fan measured 5 edges (for a 2-pole fan). For
more accurate tachometer measurement, the minimum number of edges measured may be increased.
Increasing the number of edges measured with respect to the number of poles of the fan will cause
the TACH Reading registers to indicate a fan speed that is higher or lower than the actual speed. In
order for the FSC Algorithm to operate correctly, the TACH Target must be updated by the user to
accommodate this shift. The Effective Tach Multiplier shown in
term that is applied to the Actual RPM to achieve the Reported RPM. It should only be applied if the
number of edges measured does not match the number of edges expected based on the number of
poles of the fan (which is fixed for any given fan).
Contact SMSC for recommended settings when using fans with more or less than 2 poles.
Bit 2-0 - UPDATE - determines the base time between fan driver updates. The Update Time, along
with the Fan Step Register, is used to control the ramp rate of the drive response to provide a cleaner
transition of the actual fan operation as the desired fan speed changes. The Update Time is set as
shown in
1
0
0
1
1
0
1
0
1
0
Table
RANGE[1:0]
6.34.
MINIMUM TACH
Table 6.33 Minimum Edges for Fan Rotation
EDGES
3
5
7
9
Table 6.32 Range Decode
0
0
1
0
1
DATASHEET
1 pole
2 poles (default)
3 poles
4 poles
NUMBER OF FAN POLES
Table
71
6.32.
REPORTED MINIMUM
1000 (default)
RPM
2000
4000
500
Table 6.33
MULTIPLIER (BASED ON 2
is used as a direct multiplier
EFFECTIVE TACH
POLE FANS)
Revision 1.74 (05-08-08)
TACH COUNT
MULTIPLIER
0.5
1.5
1
2
1
2
4
8