xra00 STMicroelectronics, xra00 Datasheet - Page 29

no-image

xra00

Manufacturer Part Number
xra00
Description
Uhf, Epcglobal Class 1b, Contactless Memory Chip 96 Bit Epc With Inventory And Kill Function
Manufacturer
STMicroelectronics
Datasheet
sponse Windows delineated by BIN pulses from
the Reader after a Setup time.
The 3 bits of XRA00 memory that come immedi-
ately after the matched data determine the partic-
ular Bin Response Window for an XRA00 reply.
XRA00 devices where these 3 bits are equal to
'000' respond in the first Bin Response Window,
XRA00 devices where the 3 bits are equal to '001'
reply in the second Bin Response Window...
Figure 31. PingID Answer Response Period - Reader Modulations Define Response Bins
Quiet
XRA00 devices that match the data sent by the
Reader enter the Asleep state where they no long-
er respond to Reader commands. They remain in
the Asleep state until they receive the appropriate
Talk command or after the Persistance mode time
limit is exceeded (even if power has been removed
from the XRA00).
Example of a Quiet Command. A Reader is-
sues a Quiet command containing the following
data:
[CMD] =
[PTR] =
[LEN] =
[VALUE] = 000101101
Table 11. Example of a Quiet Operation
XRA00 1 ID
XRA00 2 ID
XRA00 3 ID
XRA00 4 ID
Bit Number
00000010
00000111
00001001
Towards Highest Address Bit
EOF from CMD
Setup
b
b
b
b
...010001000001011011101010
...100111100001001010010010
...101101010001011011110110
...101100000001011011111011
...321098765432109876543210
Bin 0
(000)
(Quiet)
(x07)
(0x09)
(0x2D)
XRA00 ID Code/Bit Position
Bin 1
(001)
BIN pulses
Bin 2
(010)
Lowest Address Bit
(011)
Bin 3
XRA00 devices where the 3 bits are equal to '111'
respond in the eighth Bin Response Window.
These Bin Response Window are also called
"bins" and numbered from 0 through to 7 as shown
in
As described in the
graph, the Reader may shorten a BIn Response
Window if no tag answer is detected.
XRA00 devices will attempt to check 9 bits of their
address data, starting from bit 7, against the data
specified in the [VALUE] field. XRA00 devices
whose data matches enter the Asleep state and
remain in this state.
Once in the Asleep state the XRA00 devices will
fail to respond to any command until they receive
a Talk command or the Persistence mode limit
time is exceeded.
The XRA00 devices do not return any response to
the Quiet command.
In the example illustrated in
lined XRA00 memory bits are compared with the
[VALUE] data sent by the Reader.
After issuing the Quiet command, the Reader must
transmit seven 0’s after the EOF for the XRA00 to
execute the Quiet command. Once the seven 0’s
have been sent, the Reader is allowed to start a
new transaction.
Figure 31.
Bin 4
(100)
b
b
b
b
Bin 5
(101)
(110)
Bin 6
XRA00 execute Quiet command
Ping Reply Bin Collapse
NO (bit 10 does not match)
and become inactive
Bin 7
(111)
Table
YES
YES
YES
-
11., the under-
XRA00
ai10770
para-
29/40

Related parts for xra00