X1226 Xicor, X1226 Datasheet - Page 16

no-image

X1226

Manufacturer Part Number
X1226
Description
Real Time Clock/Calendar with EEPROM
Manufacturer
Xicor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
X1226
Manufacturer:
XICOR
Quantity:
5 510
Part Number:
X1226
Manufacturer:
XILINX
0
Part Number:
X1226
Manufacturer:
INTERSIL
Quantity:
20 000
Part Number:
X1226 EVM
Manufacturer:
P&S
Quantity:
45
Part Number:
X1226CE
Manufacturer:
NEC
Quantity:
6 219
Part Number:
X1226E
Manufacturer:
XILINX
0
Part Number:
X1226S8
Manufacturer:
XICOR
Quantity:
20 000
Part Number:
X1226S8I
Manufacturer:
XICOR
Quantity:
16
Part Number:
X1226S8I
Manufacturer:
XILINX
0
Part Number:
X1226S8IZ
Manufacturer:
INTERSIL
Quantity:
20 000
Part Number:
X1226S8IZ-2.7A
Manufacturer:
XICOR
Quantity:
20 000
Part Number:
X1226S8IZT1
Manufacturer:
INTERSIL
Quantity:
20 000
Part Number:
X1226S8ZT1
Quantity:
1 831
X1226
AC Specifications (T
Notes: (1) This parameter is not 100% tested.
TIMING DIAGRAMS
Bus Timing
REV 1.1.24 1/13/03
SCL
SDA IN
SDA OUT
Symbol
t
t
t
t
t
HD:STA
SU:DAT
HD:DAT
SU:STO
SU:STA
t
(2) Cb = total capacitance of one bus line in pF.
t
f
t
HIGH
LOW
t
SCL
t
BUF
Cb
t
DH
t
AA
t
IN
R
F
t
SU:STA
SCL Clock Frequency
Pulse width Suppression Time at inputs
SCL LOW to SDA Data Out Valid
Time the bus must be free before a new transmission can start
Clock LOW Time
Clock HIGH Time
Start Condition Setup Time
Start Condition Hold Time
Data In Setup Time
Data In Hold Time
Stop Condition Setup Time
Data Output Hold Time
SDA and SCL Rise Time
SDA and SCL Fall Time
Capacitive load for each bus line
A
= -40°C to +85°C, VCC = +2.7V to +5.5V, unless otherwise specified.)
t
HD:STA
t
F
t
SU:DAT
t
HIGH
Parameter
www.xicor.com
t
LOW
t
HD:DAT
t
R
t
AA
Characteristics subject to change without notice.
t
DH
20 +.1Cb
20 +.1Cb
Min.
50
100
0.1
1.3
1.3
0.6
0.6
0.6
0.6
50
0
t
(1)
BUF
(2)
(2)
t
SU:STO
Max. Units
400
300
300
400
0.9
16 of 24
kHz
pF
ns
µs
µs
µs
µs
µs
µs
ns
µs
µs
ns
ns
ns