M41ST85W_11 STMICROELECTRONICS [STMicroelectronics], M41ST85W_11 Datasheet - Page 24

no-image

M41ST85W_11

Manufacturer Part Number
M41ST85W_11
Description
3.0/3.3 V I2C combination serial RTC, NVRAM supervisor and microprocessor supervisor
Manufacturer
STMICROELECTRONICS [STMicroelectronics]
Datasheet
Clock operation
Figure 16. Backup mode alarm waveform
3.5
Note:
Note:
24/43
V CC
V PFD
V SO
ABE, AFE Bits in Interrupt Register
AF bit in Flags Register
IRQ/FT/OUT
Watchdog timer
The watchdog timer can be used to detect an out-of-control microprocessor. The user
programs the watchdog timer by setting the desired amount of time-out into the watchdog
register, address 09h. Bits BMB4-BMB0 store a binary multiplier and the two lower order bits
RB1-RB0 select the resolution, where 00 = 1/16 second, 01 = 1/4 second, 10 = 1 second,
and 11 = 4 seconds. The amount of time-out is then determined to be the multiplication of
the five-bit multiplier value with the resolution. (For example: writing 00001110 in the
watchdog register = 3*1 or 3 seconds).
The accuracy of the timer is within ± the selected resolution.
If the processor does not reset the timer within the specified period, the M41ST85W sets the
WDF (watchdog flag) and generates a watchdog interrupt or a microprocessor reset.
The most significant bit of the watchdog register is the watchdog steering bit (WDS). When
set to a '0,' the watchdog will activate the IRQ/FT/OUT pin when timed-out. When WDS is
set to a '1,' the watchdog will output a negative pulse on the RST pin for t
register, FT, AFE, ABE and SQWE bits will reset to a '0' at the end of a watchdog time-out
when the WDS bit is set to a '1.'
The watchdog timer can be reset by two methods: 1) a transition (high-to-low or low-to-high)
can be applied to the watchdog input pin (WDI) or 2) the microprocessor can perform a
WRITE of the watchdog register. The time-out period then starts over.
The WDI pin should be tied to V
In order to perform a software reset of the watchdog timer, the original time-out period can
be written into the watchdog register, effectively restarting the count-down cycle.
Should the watchdog timer time-out, and the WDS bit is programmed to output an interrupt,
a value of 00h needs to be written to the watchdog register in order to clear the IRQ/FT/OUT
HIGH-Z
Doc ID 7531 Rev 11
SS
if not used.
trec
HIGH-Z
rec
. The watchdog
AI03920
M41ST85W