A “Byte Write” operation to Control register 1 or 3, causes
the value in the nonvolatile cells of the other to be recalled
into the corresponding volatile cells, as during power-up.
When reading either of the control registers 1 or 3, the Data
Bytes are always the content of the corresponding
nonvolatile cells, even if bit NV13 is “0” (Figure 5).
Read Operation
A Read operation consist of a three byte instruction followed
by one or more Data Bytes (See Figure 18). The master
initiates the operation issuing the following sequence: a
START, the Slave Address byte with the R/W bit set to “0”,
an Address Byte, a second START, and a second Slave
Address byte with the R/W bit set to “1”. After each of the
three bytes, the X96011 responds with an ACK. Then the
X96011 transmits Data Bytes as long as the master
responds with an ACK during the SCL cycle following the
eigth bit of each byte. The master terminates the read
operation (issuing a STOP condition) following the last bit of
the last Data Byte (Figure 18).
The Data Bytes are from the memory location indicated by
an internal pointer. This pointer initial value is determined by
the Address Byte in the Read operation instruction, and
increments by one during transmission of each Data Byte.
After reaching the memory location CFh a stop should be
FROM THE
SIGNALS
MASTER
SIGNALS FROM
SIGNAL AT
THE SLAVE
SDA
S
A
R
T
T
1
0
1
ADDRESS
R/W = 0
SLAVE
0
WITH
17
0
A
C
K
ADDRESS
BYTE
FIGURE 18. READ SEQUENCE
A
C
K
A
R
S
T
T
X96011
1
0
ADDRESS
R/W = 1
1
SLAVE
WITH
0
issued. If the read operation continues the output bytes are
unpredictable. If the byte address is set between 00h and
7Fh, or higher than CFh, the output bytes are unpredictable.
A Read operation internal pointer can start at any memory
location from 80h through CFh, when the Address Byte is
80h through CFh respectively.
When reading any of the control registers 1, 2, 3, or 4, the
Data Bytes are always the content of the corresponding
nonvolatile cells, even if bit NV13 is "0". See “IDS: Current
Generator Direction Select Bit (Non-volatile)”. See Figure 5.
Data Protection
There are three levels of data protection designed into the
X96011: 1- Any Write to the device first requires setting of
the WEL bit in Control 6 register; 2- The Write Protection pin
disables any writing to the X96011; 3- The proper clock count,
data bit sequence, and STOP condition is required in order to
start a nonvolatile write cycle, otherwise the X96011 ignores
the Write operation.
WP: Write Protection Pin
When the Write Protection (WP) pin is active (LOW), any
Write operations to the X96011 is disabled, except the
writing of the WEL bit. See
1
A
C
K
FIRST READ
DATA BYTE
A
C
K
A
C
K
LAST READ
DATA BYTE
February 25, 2008
FN8215.2
O
S
T
P