Data in ADRRH and ADRRL should be read only when the A/D start flag (ADSF) in the A/D
start register (ADSR) is cleared to 0.
Changing the digital input signal at an adjacent pin during A/D conversion may adversely
affect conversion accuracy.
When A/D conversion is started after clearing module standby mode, wait for 10 ø clock
cycles before starting.
In active mode and sleep mode, the analog power supply current (AI
) flows in the ladder
STOP1
resistance even when the A/D converter is on standby. Therefore, if the A/D converter is not
used, it is recommended that AV
be connected to the system power supply and the
CC
ADCKSTP (A/D converter module standby mode control) bit be cleared to 0 in clock stop
register 1 (CKSTPR1).