LUCL9310AP-D AGERE [Agere Systems], LUCL9310AP-D Datasheet - Page 16

no-image

LUCL9310AP-D

Manufacturer Part Number
LUCL9310AP-D
Description
Line Interface and Line Access Circuit Full-Feature SLIC,Ringing Relay,and Test Access Device
Manufacturer
AGERE [Agere Systems]
Datasheet
Full-Feature SLIC, Ringing Relay, and Test Access Device
State Definitions
Primary Control Modes
Powerup, Forward Battery
Powerup, Reverse Battery
16
Normal talk and battery feed state.
Pin PT is positive with respect to pin PR.
All ac transmission and dc feed circuits are powered
up.
On-hook transmission is enabled.
Thermal shutdown is active.
Battery window comparator sense shutdown is on.
Switch break switches (SW1 and SW2) are closed,
and ring access switches (SW3 and SW4) are open.
V
tions.
Automatic battery switch selects V
ing off-hook conditions.
All supervision circuits except for ring trip detector
are active.
Overhead is set via pin OVH.
TESTLEV output is in the high-impedance mode,
and TESTSIG input is off unless this feature is
selected via the secondary control table.
PPMOUT is in the high-impedance mode, and
PPMIN input is off unless this feature is selected via
the secondary control table.
NSTAT represents the loop closure detector status.
Normal talk and battery feed state.
Pin PR is positive with respect to pin PT.
All ac transmission and dc feed circuits are powered
up.
On-hook transmission is enabled.
Thermal shutdown is active.
Battery window comparator sense shutdown is on.
Switch break switches (SW1 and SW2) are closed,
and ring access switches (SW3 and SW4) are open.
V
tions.
BAT1
BAT1
is applied to tip and ring during on-hook condi-
is applied to tip and ring during on-hook condi-
BAT1
or V
BAT2
dur-
Scan
Ground Start
Automatic battery switch selects V
off-hook conditions.
All supervision circuits except for ring trip detector
are active.
Overhead is set via pin OVH.
TESTLEV output is in the high-impedance mode,
and TESTSIG input is off unless this feature is
selected via the secondary control table.
PPMOUT is in the high-impedance mode, and
PPMIN input is off unless this feature is selected via
the secondary control table.
NSTAT represents the loop closure detector status.
Scan clamp circuitry is active.
Loop closure is active.
All ac transmission, dc feed, and other supervision
circuits, including ring trip, are shut down.
PPM is powered down.
Thermal shutdown is active.
Battery window comparator sense shutdown is on.
On-hook transmission is disabled.
Pin PT is positive with respect to PR, and V
applied to tip/ring.
Switch break switches (SW1 and SW2) are closed,
and ring access switches (SW3 and SW4) are open.
When the scan clamp circuitry is on, overhead volt-
age is fixed and not controlled by OVH. Also the cur-
rent limit is not the normal current limit set at V
NSTAT represents the loop closure detector status.
Tip amplifier is on, tip break switch is open.
The device presents a high impedance (>100 k ) to
pin PT and a current-limited battery (V
Common-mode current detector is on.
Ring trip detector is off.
Output TRGDET indicates current flowing in the ring
lead.
This is not a defined state in the primary control
mode table. It is achieved via the powerup and the
ring amp states in the primary control mode table.
Agere Systems Inc.
BAT1
or V
BAT2
July 2001
) to PR.
BAT2
BAT1
under
PROG
is
.

Related parts for LUCL9310AP-D