Electrical Characteristics
Test
Table 8. ac Test Source
1. ac test signal should be ac coupled into TESTSIG.
2. A pull-down resistor to V
3. This parameter is not tested in production, it is guaranteed by design and characterization.
Table 9. Test Sense
1. This is the voltage coefficient with respect to tip/ring voltage. See Table 21 TESTLEV Output Options (Tip-to-Ring, Tip-to-Ground, and Ring-
2. This parameter is not tested in production, it is guaranteed by design and characterization.
22
Test Source
Single-ended Voltage Gain ±10 V on Tip/Ring
Differential Voltage Gain ±10 V on Tip/Ring
Voltage Gain Accuracy (single-ended or differential)
Voltage Coefficient
Current Gain at VTX (dc) Differential
Current Gain at VTX (dc) Single-ended
Current Gain at VITR (ac) Differential
Current Gain at VITR (ac) Single-ended
Overload at VTX
Overload at VITR
V
V
TESTLEV Offset Relative to V
TESTLEV Amplifier
REF
REF
Frequency (f1)
Signal Gain (TESTSIG to amplifier outputs) V
Signal Gain Voltage Coefficient
Input Signal
Harmonic Distortion
Output Voltage Swing
Input Voltage Swing
to-Ground equations) for application of this parameter.
Accuracy
1, 2
:
2
2
Parameter
REF
3
should be connected to TESTSIG.
Parameter
REF
(continued)
TESTSIG
= 0.35 V
AGND + 0.35
AGND + 0.35
145.5
±105
–3.5
19.6
Min
291
–40
9.8
±7
–5
Min
0
0.01
1/75
2.35
1/75
Typ
300
150
20
10
1
1.27
Typ
10
V
V
CC
CC
154.5
Max
20.4
10.2
309
3.5
40
5
– 0.4
– 1.0
Max
1.25
Agere Systems Inc.
100
5
July 2001
Unit
%/V
V/A
V/A
V/A
V/A
mA
mA
mV
%
%
Vrms
V
V
V
Unit
kHz