ICX224 SONY [Sony Corporation], ICX224 Datasheet - Page 46

no-image

ICX224

Manufacturer Part Number
ICX224
Description
Timing Generator and Signal Processor for Frame Readout CCD Image Sensor
Manufacturer
SONY [Sony Corporation]
Datasheet
CXD3410GA
OB clamp level setting data: D12 to D15 OBLVL [OB clamp level]
The CXD3410GA can set the OPB clamp output value from 0 to 60LSB in 4LSB steps by using CCD signal
processor block control data D12 to D15 OBLVL.
The OPB clamp output setting data is expressed as shown in the table below using D12 to D15 OBLVL.
MSB
LSB
D12 D13 D14 D15
0
1
1
0
OBLVL is expressed as 6h .
6
For example, when OBLVL is set to "0h", "1h", "8h" and "Fh", the respective OPB clamp output setting values
are 0LSB, 4LSB, 32LSB and 60LSB.
– 46 –