11. Operating conditions
Power supply:
Power consumption:
Dielectric strength:
Insulation resistance:
Ambient temperature:
Ambient humidity:
Enclosure:
Enclosure class: Front IP65 (IEC 529)
Nameplate:
Dimensions:
VARIOUS CONTROL EXAMPLES
Basic type PID V control (Fixed
function)
PID control
Cascade control
This is a PID control function
which is fixedly defined be-
forehand. The definition can
be made through simple opera-
tion, and wafer connection is
unnecessary.
(Computation elements such
as square root, filter, limiter,
non-linear etc. can be made
valid or invalid through speci-
fication.)
Fixed value control is carried out
by using only the MAln control
block. PID control by means of
an external set point is also
p e r f o r m e d .
elements such as square root,
filter, limiter, non-linear etc. can
be made valid or invalid through
specification.)
Cascade control is carried out
by combining two PID con-
trol blocks.
output of the SUB PID con-
troller follow up the set point
of the MAln PID controller, A
and R can be changed over
balancelessly.
By having the
( C o m p u t a t i o n
Selectable from the following 3 types
24V DC (20 to 30V DC), 100V AC (85 to
132V/47 to 63Hz AC), 200V AC (187 to
264V/47 to 63Hz AC)
Approx. 12W (DC), 20VA (AC)
1500V AC for 1 minute
100M
0 to 50 C
90%RH or less
Steel case
100(H) x 70(W), white acrylic
144(H) x 72(W) x 391(D)mm, IEC (DIN)
standards
or more at 500V DC
PV tracking
command
External set
point
Process
variable for
SUB PID
Process
variable for
MAIn PID
set point
Process
External
set point
variable
Process
External
variable
SH
SH
SH
SL
SL
SL
Filter
A.M
R
EXT
Filter
Filter
INT
R
A.M
Non-linear
Mass{weight}:
Mounting method:
Finish color:
Range of delivery: Controller and mounting bracket
Item prepared separately:
Filter
SUB PID
PH
Non-linear
PL
In other than remote mode, output tracking is
applied to the set point of MAIn PID.
H
DV
L
H
SH
DV
L
SL
MAIn control block
D
P
I
(MAIn PID)
Approx. 2.9kg
Flush on indoor panel; vertical mounting
is standard
Mounting on tilted surface possible (Angle
Munsell N1.5 for front panel and case
Transmission cable (Type PNZ)
)
D
P
I
R
A.M
PV
SV
=0 to 90
MAIn PID
MH
MH
MV
MV
ML
ML
M
R.A
R.A
M
R.A
M
output
output
output
PO
PO
PO