EDS11-113D FUJI [Fuji Electric], EDS11-113D Datasheet - Page 3

no-image

EDS11-113D

Manufacturer Part Number
EDS11-113D
Description
FC SERIES MANUAL LOADER(CONTINUOUS OUTPUT TYPE)
Manufacturer
FUJI [Fuji Electric]
Datasheet
Control output abnormality:
Fault contents indication:
6. Transmission functions
(1) Transmission items
Setting operation items:
(2) Transmission setting inhibit:
(3) Communication interface
(a) T-link: Private interface
(b) RS-422A/485: Universal interface
7. Other functions
Data protective function by use of pass code
8. Additional functions (options)
(1) Hard manual unit (HMV)
Control output:
Allowable load resistance:
9. Operating conditions
Power supply:
Power consumption:
Dielectric strength:
Insulation resistance:
Ambient temperature:
Supervisory items:
Parameter setting enable/inhibit can be designated by
transmission from the host. Designation is done by keys
on the front panel.
Transmission speed: 500Kbps
No. of units connectable: 32 max.
Transmission distance: 1km max.
Transmission form: Multi-drop
Control method: I/O transmission and message
Transmission speed: 2400, 4800, 9600 or 19200bps
No. of units connectable: 31 max.
Transmission distance: 1km max.
Transmission form: Multi-drop
Control method: Polling/selecting
FLT lamp lights and FLT contact output
goes "ON"
Other function is processed at all times.
Cause of fault is indicated numerically on
numerical indicator on the front panel.
PNB
Process value, control output, operation
mode, alarm information, fault informa-
tion, various limiter values, constants, etc.
Host
Control output, operation mode, various
limiter values, constants, etc.
4 to 20mA DC
600 or less (24V DC power supply)
Selected from the following 3 types
24V DC (20 to 30V DC)
110V AC (85 to 132V/47 to 63Hz AC)
220V AC (187 to 264V/47 to 63Hz AC)
Approx. 11W (DC)
Approx. 20VA (AC)
1500V AC, 1 min.
100M or more at 500V DC
0 to 50 C
host
PNB
configurable
Ambient humidity:
Enclosure:
Rating plate (Name plate):
Dimensions:
Mass {weight}:
Mounting method:
Finish color:
Scope of delivery: Manual loader and mounting bracket
Item to be ordered separately:
CODE SYMBOLS
1 2 3 4 5 6 7 8
P N B 3
D
G
A
B
C
E
F
A
B
1
2
3
Note: Front scale and temperature range are to be se-
5 -
9 10
0
1
lected and specified from the "STANDARD
FRONT SCALE" and "STANDARD TEMPERATURE
RANGE" stated hereafter, when order being
placed.
90% RH or less
Steel case
100 (H) x 72 (W) mm, white acryl
144 (H) x 72 (W) x 407 (D) mm, IEC
(DIN) standards
Approx. 2.9kg
Flush with indoor panel; vertical mounting
is standard.
Mounting on tilted surface possible
Munsell N 1.5 for front panel and case
Communication cable (type PNZ)
Y
T
R
S
(angle " ")
Power supply
24V DC (20 to 30V DC)
110V AC (85 to 132V/47 to 63Hz AC)
220V AC (187 to 264V/47 to 63Hz AC)
Hard manual back-up unit
Without
With
Process value input signal
1 to 5V DC
4 to 20mA DC with 24V DC power supply
J thermocouple
K thermocouple
E thermocouple
R thermocouple
RTD Pt100 3-wire type, 50 C span or more
External MV inputs
one 1 to 5V DC
one 4 to 20mA DC
Transmission function
Without
T-link
RS-422A
RS-485
=0 to 90
Description
10mV DC span or more,
cold junction compen-
sation comprised
3

Related parts for EDS11-113D