AP-CF512ME3FR-NRJ Apacer, AP-CF512ME3FR-NRJ Datasheet - Page 34

no-image

AP-CF512ME3FR-NRJ

Manufacturer Part Number
AP-CF512ME3FR-NRJ
Description
Memory Cards CFC 3 STD TMP 512MB COMPACT FLASH CARD
Manufacturer
Apacer
Datasheet

Specifications of AP-CF512ME3FR-NRJ

Rohs
yes
Product
Compact Flash
Memory Size
512 MB
Operating Supply Voltage
3.3 V, 5 V
Maximum Operating Temperature
+ 70 C
Dimensions
42.8 mm x 36.4 mm x 3.3 mm
Minimum Operating Temperature
0 C
All returned data comply with the SMART data structure as specified in the ATA spec. Bytes 0 to 361 of
the structure returns SST specific data that depends of the requested subcommand. Bytes 362 to 385 are
standard values as defined in the ATA spec. bytes 386 to 510 returns SST specific data common to all
subcommands. Byte 511 is the 2’s complement checksum of all bytes in the data structure.
Offline Data Collection Status (byte 362)
The offline data collection status byte indicates whether SMART data collection was successful or not.
The host should check this value in the returned data structure before proceeding with interpretation of
vendor specific data bytes. The follow are possible status values.
6.1.21 Set-Multiple-Mode – C6H
This command enables the compact flash card to perform Read and Write Multiple operations and
establishes the block count for these commands. The Sector Count register is loaded with the number of
sectors per block. Upon receipt of the command, the compact flash card sets BSY to 1 and checks the
Sector Count register.
If the Sector Count register contains a valid value and the block count is supported, the value is loaded
for all subsequent Read-Multiple and Write-Multiple commands and execution of those commands is
enabled. If a block count is not supported, an Aborted command error is posted, and Read- Multiple and
Write- Multiple commands are disabled. If the Sector Count registers contains 0 when the command is
issued, Read and Write- Multiple commands are disabled. At power-on, or after a hardware or (unless
disabled by a Set-Feature command) software reset, the default mode is Read and Write-Multiple
disabled.
© 2009 Apacer Technology Inc.
Command (7)
Sec Num (3)
Cyl High (5)
Cyl Low (4)
Sec Cnt (2)
Feature (1)
Value
00H
02H
04H
05H
06H
C/D/H (6)
Bit ->
Value Added
Value Added
Value Added
Value Added
7
Definition
Offline data collection activity was never started.
Offline data collection activity was completed without error.
Offline data collection activity was suspended host.
Offline data collection activity was aborted by host.
Offline data collection activity was aborted by device.
AP-CFxxxxE3XR-XXXXJ
6
X
Compact Flash Ⅲ Ⅲ Ⅲ Ⅲ series
5
33
Drive
4
Sector Count
C6H
X
X
X
X
3
2
X
1
Rev. 1.6
0

Related parts for AP-CF512ME3FR-NRJ