AP-CF512ME3FR-NRJ Apacer, AP-CF512ME3FR-NRJ Datasheet - Page 50

no-image

AP-CF512ME3FR-NRJ

Manufacturer Part Number
AP-CF512ME3FR-NRJ
Description
Memory Cards CFC 3 STD TMP 512MB COMPACT FLASH CARD
Manufacturer
Apacer
Datasheet

Specifications of AP-CF512ME3FR-NRJ

Rohs
yes
Product
Compact Flash
Memory Size
512 MB
Operating Supply Voltage
3.3 V, 5 V
Maximum Operating Temperature
+ 70 C
Dimensions
42.8 mm x 36.4 mm x 3.3 mm
Minimum Operating Temperature
0 C
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
© 2009 Apacer Technology Inc.
All timing measurement switching points (low-to-high and high-to-low) are taken at 1.5V.
All signal transitions for a timing parameter are measured at the connector specified in the measurement location column. For
example, in the case of TRFS, both STROBE and DMARDY Transitions are measured at the Sender connector.
The parameter TCYC is measured at the recipient’s connector farthest from the Sender.
80-Conductor cabling is required in order to meet sup (TDS, TCS) and hold (TDH, TCH) times in modes greater than two.
The parameters TDS and TDH for Mode 5 are defined for a Recipient at the end of the cable only in a configuration with a
single device located at the end of the cable. This could result in the minimum values for TDS and TDH for mode 5 at the
middle connector being 3.0 and 3.9 ns respectively.
Timing for TDVS, TDVH, TCVS, and TCVH are met for lumped capacitive loads of 15 and 50 pf at the connector where the
Data and STROBE signals have the same capacitive load value. Due to reflections on the cable, these timing measurements
are not valid in a normally functioning system.
The parameters TUI, TMLI, and TLI indicate Sender-to-Recipient or Recipient-to-Sender interlocks. For example, one agent
(either Sender or Recipient) is waiting for the other agent to respond with a signal before proceeding; TUI is an unlimited
interlock that has no maximum time value, TMLI is a limited time-out that has a defined minimum, and TLI is a limited time-out
that has a defined maximum.
The parameter TLI is measured at the connector of the Sender or Recipient that is responding to an incoming transition from
the Recipient or Sender respectively. Both the incoming signal and the outgoing response are measured at the same
connector.
The parameter TAZ is measured at the connector of the Sender or Recipient that is driving the bus but must release the bus
that allow for a bus turnaround.
For all modes the parameter TZIORDY may be greater than TENV because the host has a pull-on IORDY giving it a known
state when released.