Si87xxSOIC8-KIT Silicon Labs, Si87xxSOIC8-KIT Datasheet - Page 6

no-image

Si87xxSOIC8-KIT

Manufacturer Part Number
Si87xxSOIC8-KIT
Description
Interface Development Tools SOIC8 Evaluation Kit
Manufacturer
Silicon Labs
Type
Isolatorsr
Datasheet

Specifications of Si87xxSOIC8-KIT

Rohs
yes
Product
Evaluation Kits
Tool Is For Evaluation Of
SI87xxSOIC8
Si87xx
Table 3. Regulatory Information (Pending)*
Table 4. Insulation and Safety-Related Specifications
6
CSA
The Si87xx is certified under CSA Component Acceptance Notice 5A. For more details, see File 232873.
61010-1: Up to 600 V
60950-1: Up to 1000 V
voltage.
60601-1: Up to 250 V
VDE
The Si87xx is certified according to IEC 60747-5-2. For more details, see File 5006301-4880-0001.
60747-5-2: Up to 1414 V
UL
The Si87xx is certified under UL1577 component recognition program. For more details, see File E257455.
Rated up to 5000 V
CQC
The Si87xx is certified under GB4943.1-2011. For more details, see File number pending.
Rated up to 1000 V
*Note: Regulatory Certifications apply to 3.75 kV
Nominal Air Gap (Clearance)
Nominal External Tracking
(Creepage)
Minimum Internal Gap
(Internal Clearance)
Tracking Resistance
(Proof Tracking Index)
Erosion Depth
Resistance (Input-Output)*
Capacitance (Input-Output)*
*Note: To determine resistance and capacitance, the Si87xx is converted into a 2-terminal device. Pins 1–4 (1–3, SDIP6) are
Regulatory Certifications apply to 5.0 kV
For more information, see "9.Ordering Guide" on page 20.
shorted together to form the first terminal, and pins 5–8 (4–6, SDIP6) are shorted together to form the second terminal.
The parameters are then measured between these two terminals.
Parameter
RMS
RMS
RMS
RMS
RMS
isolation voltage for basic protection.
reinforced insulation working voltage; up to 1000 V
peak
reinforced insulation working voltage; up to 600 V
reinforced insulation working voltage; up to 500 V
reinforced insulation working voltage; up to 1000 V
for reinforced insulation working voltage.
Symbol
L(IO1)
L(IO2)
PTI
R
C
ED
IO
IO
RMS
Test Condition
RMS
IEC60112
f = 1 MHz
Preliminary Rev. 0.5
rated devices which are production tested to 6.0 kV
rated devices which are production tested to 4.5 kV
SOIC-8
4.9 min
4.8 min
0.016
0.031
10
600
1
12
7.4 min
8.0 min
0.016
0.031
DIP8
RMS
10
600
RMS
RMS
1
12
RMS
basic insulation working voltage.
Value
basic insulation working voltage.
basic insulation working voltage.
basic insulation working
Pending
8.0 min
8.0 min
SDIP6
0.016
10
600
1
12
RMS
10.0 min
RMS
9.6 min
LGA8
0.016
0.021
10
600
for 1 sec.
1
for 1 sec.
12
Unit
mm
mm
mm
mm
pF
V

Related parts for Si87xxSOIC8-KIT