M25P64-VMF6P NUMONYX, M25P64-VMF6P Datasheet - Page 40
M25P64-VMF6P
Manufacturer Part Number
M25P64-VMF6P
Description
IC FLASH 64MBIT 50MHZ 16SOIC
Manufacturer
NUMONYX
Series
Forté™r
Specifications of M25P64-VMF6P
Format - Memory
FLASH
Memory Type
FLASH
Memory Size
64M (8M x 8)
Speed
50MHz
Interface
SPI, 3-Wire Serial
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
16-SOIC
Memory Configuration
8M X 8
Ic Interface Type
Serial, SPI
Clock Frequency
75MHz
Supply Voltage Range
2.7V To 3.6V
Memory Case Style
SOIC
No. Of Pins
16
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
M25P64-VMF6P
Manufacturer:
ST
Quantity:
7 093
Part Number:
M25P64-VMF6P
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
M25P64-VMF6P,M25P64-VMF6TP
Manufacturer:
ADI
Quantity:
379
Company:
Part Number:
M25P64-VMF6P-6JBS
Manufacturer:
RENESAS
Quantity:
1 350
10
40/55
DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC Characteristic tables that
follow are derived from tests performed under the Measurement Conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Table 10.
1. Avoid applying VPPH to the W/VPP pin during Bulk Erase with process technology T9HX devices,
2. "Autograde 6 and Standard parts (grade 6) are tested to 85
3. Autograde 3 is tested to 125
Table 11.
Table 12.
1. Output Hi-Z is defined as the point where data out is no longer driven.
Symbol
Symbol
Program / erase cycles
T
V
identified by process identification digit "4" in the device marking.
V
AVPP
T
T
C
PPH
CC
A
A
L
Data retention
Parameter
Supply Voltage
Supply Voltage on W/V
mode
Ambient Operating Temperature (grade 6)
Ambient Operating Temperature (grade 3)
Ambient Operating Temperature for Fast
Program/Erase mode
Load Capacitance
Input Rise and Fall Times
Input Pulse Voltages
Input Timing Reference Voltages
Output Timing Reference Voltages
Operating conditions
AC measurement conditions
Data Retention and Endurance
(1)
Grade 3, Autograde 6, Grade 6
at 55°C
°
C.
Parameter
Parameter
PP
pin for Fast Program/Erase
Condition
(2)
(3)
°
C, but the Autograde 6 will follow the HRCF.
100,000
Min.
20
Min.
0.2V
0.3V
Min.
–40
–40
2.7
8.5
15
CC
CC
V
CC
Max.
30
to 0.8V
to 0.7V
/ 2
Typ
25
Max.
5
CC
CC
Cycles per sector
Max.
125
years
3.6
9.5
85
35
Unit
Unit
pF
ns
V
V
V
Unit
°C
°C
°C
V
V