L6566B STMicroelectronics, L6566B Datasheet - Page 37

IC CTRLR OVP OTP UVLO HV 16SOIC

L6566B

Manufacturer Part Number
L6566B
Description
IC CTRLR OVP OTP UVLO HV 16SOIC
Manufacturer
STMicroelectronics
Datasheet

Specifications of L6566B

Output Isolation
Isolated
Frequency Range
10 ~ 300kHz
Voltage - Input
8 ~ 23 V
Power (watts)
750mW
Operating Temperature
-40°C ~ 150°C
Package / Case
16-SOIC (0.154", 3.90mm Width)
Output Current
800 mA
Output Power
750 mW
Input Voltage
8 V to 23 V
Operating Temperature Range
- 40 C to + 150 C
Mounting Style
SMD/SMT
Duty Cycle (max)
75 %
Selectable Multi-mode Operation
fixed frequency or quasi-resonant
For Use With
497-6452 - BOARD EVAL FOR L6566B497-6451 - BOARD EVAL FOR L6566B497-6450 - BOARD EVAL FOR L6566B497-6449 - BOARD EVAL FOR L6566A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
L6566B
Manufacturer:
ST
Quantity:
20 000
Part Number:
L6566B
Quantity:
400
Part Number:
L6566BH
Manufacturer:
ST
0
Part Number:
L6566BHTR
Manufacturer:
ST
0
Part Number:
L6566BHTR
Manufacturer:
ST
Quantity:
20 000
Part Number:
L6566BHTR
0
Part Number:
L6566BTR
Manufacturer:
ST
0
Part Number:
L6566BTR
0
Company:
Part Number:
L6566BTR
Quantity:
9 000
Company:
Part Number:
L6566BTR
Quantity:
9 000
Part Number:
L6566BTR-13
Manufacturer:
ST
Quantity:
20 000
Part Number:
L6566BTR@@@@@@@@
Manufacturer:
ST
0
L6566B
5.12
Equation 15
where T
Brownout protection
Brownout protection is basically a not-latched device shutdown function activated when a
condition of mains undervoltage is detected. There are several reasons why it may be
desirable to shut down a converter during a brownout condition, which occurs when the
mains voltage falls below the minimum specification of normal operation.
Firstly, a brownout condition may cause overheating of the primary power section due to an
excess of RMS current. Secondly, spurious restarts may occur during converter power
down, hence causing the output voltage not to decay to zero monotonically.
L6566B shutdown upon brownout is accomplished by means of an internal comparator, as
shown in the block diagram of
inverting input of the comparator, available on the AC_OK pin (16), is supposed to sense a
voltage proportional to the RMS (peak) mains voltage; the non-inverting input is internally
referenced to 0.485 V with 35 mV hysteresis. If the voltage applied on the AC_OK pin before
the device starts operating does not exceed 0.485 V or if it falls below 0.45 V while the
device is running, the AC_FAIL signal goes high and the device shuts down, with the soft-
start capacitor discharged and the gate-drive output low. Additionally, if the device has been
latched off by some protection function (testified by Vcc oscillating between V
V
quicker restart as the input source is removed.
While the brownout protection is active the start-up generator keeps on working but, being
there no PWM activity, the Vcc voltage continuously oscillates between the start-up and the
HV generator restart thresholds, as shown in the timing diagram of
Figure 24. Maximum allowed duty cycle vs switching frequency for correct OVP
ccON
- 0.5 V) the AC_OK voltage falling below 0.45 V clears the latch. This may allow a
BLANK2
detection
Dmax
= 2 µs; this is also illustrated in the diagram of
0.8
0.7
0.6
0.5
0.4
0.3
0.2
5 . 10
4
1 . 10
Figure 25 on page 38
5
1.5 . 10
D
+
5
T
BLANK
2 . 10
5
fsw [Hz]
2
f
sw
2.5 . 10
, which shows the basic usage. The
1
5
3 . 10
5
Figure 24
3.5 . 10
Application information
Figure 25
5
0.725
.
4 . 10
5
.
ccON
and
37/51

Related parts for L6566B