LTC1760CFW#PBF Linear Technology, LTC1760CFW#PBF Datasheet - Page 20

IC MANAGER BATTERY DUAL 48TSSOP

LTC1760CFW#PBF

Manufacturer Part Number
LTC1760CFW#PBF
Description
IC MANAGER BATTERY DUAL 48TSSOP
Manufacturer
Linear Technology
Datasheet

Specifications of LTC1760CFW#PBF

Function
Charge Management
Battery Type
Smart Batteries
Voltage - Supply
6 V ~ 28 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
48-TFSOP (0.240", 6.10mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
LTC1760CFW#PBFLTC1760CFW
Manufacturer:
Linear Technology
Quantity:
1 855
Company:
Part Number:
LTC1760CFW#PBFLTC1760CFW
Manufacturer:
ST
Quantity:
215
Company:
Part Number:
LTC1760CFW#PBFLTC1760CFW
Manufacturer:
LT
Quantity:
1 000
Company:
Part Number:
LTC1760CFW#PBFLTC1760CFW
Manufacturer:
LT/凌特
Quantity:
20 000
Company:
Part Number:
LTC1760CFW#PBF
Manufacturer:
LT
Quantity:
2
LTC1760
OPERATIO
20
2.3.7 Current() ('h0a)
Description:
This function is used by the LTC1760 to read the actual
current being supplied through the battery terminals.
Purpose:
Allows the LTC1760 to determine how much current a
battery is receiving through its terminals and close the
charging current servo loop.
SMBus Protocol: Read Word. LTC1760 reads Battery 1 or
Battery 2 as an SMBus Master.
Output: signed integer (2’s complement) — charge/dis-
charge rate in mA increments - positive for charge, nega-
tive for discharge. Refer to "Section 2.2" for bit mapping.
Units: mA.
Range: 0 to 32,767 mA for charge or 0 to -32,768 mA for
discharge.
2.3.8 ChargingCurrent() ('h14)
Description:
This function is used by the LTC1760 to read the Smart
Battery’s desired charging current.
Purpose:
Allows the LTC1760 to determine the maximum charging
current.
SMBus Protocol: Read Word. LTC1760 reads Battery 1 or
Battery 2 as an SMBus Master.
Output: unsigned integer — maximum charger output
current in mA. Refer to "Section 2.2" for bit mapping.
Units: mA.
Range: 0 to 65,534 mA.
2.3.9 ChargingVoltage() ('h15)
Description:
This function is used by the LTC1760 to read the Smart
Battery’s desired charging voltage.
U
Purpose:
Allows the LTC1760 to determine the maximum charging
voltage.
SMBus Protocol: Read Word. LTC1760 reads Battery 1 or
Battery 2 as an SMBus Master.
Output: unsigned integer — charger output voltage in mV.
Refer to Section 2.2 for bit mapping.
Units: mV.
Range: 0 to 65,534 mV.
2.3.10 AlarmWarning () ('h16)
Description:
This function is used by the LTC1760 to read the Smart
Battery alarm register.
Purpose:
Allows the LTC1760 to determine the state of all applicable
alarm flags.
SMBus Protocol: Read Word. LTC1760 reads Battery 1 or
Battery 2 as an SMBus Master.
Output: unsigned integer – Refer to “Section 2.2” for bit
mapping.
OVER_CHARGED_ALARM Bit
The read only OVER_CHARGED_ALARM bit is used by the
LTC1760 to determine if charging may continue.
Allowed values are:
TERMINATE_CHARGE_ALARM Bit
The read only TERMINATE_CHARGE_ALARM bit is used
by the LTC1760 to determine if charging may continue.
Allowed values are:
'b1: The LTC1760 will not charge this battery.
'b0: The LTC1760 may charge this battery if other
conditions permit charging.
'b1: The LTC1760 will not charge this battery.
'b0: The LTC1760 may charge this battery if other
conditions permit charging.
1760f