ISL6742AAZA Intersil, ISL6742AAZA Datasheet - Page 7

IC CTRLR PWM DOUBLE ENDED 16QSOP

ISL6742AAZA

Manufacturer Part Number
ISL6742AAZA
Description
IC CTRLR PWM DOUBLE ENDED 16QSOP
Manufacturer
Intersil
Datasheet

Specifications of ISL6742AAZA

Pwm Type
Voltage/Current Mode
Number Of Outputs
4
Frequency - Max
2MHz
Duty Cycle
100%
Voltage - Supply
9 V ~ 16 V
Buck
No
Boost
No
Flyback
No
Inverting
No
Doubler
No
Divider
No
Cuk
No
Isolated
No
Operating Temperature
-40°C ~ 105°C
Package / Case
16-QSOP
Frequency-max
2MHz
Peak Reflow Compatible (260 C)
Yes
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ISL6742AAZA-T
Manufacturer:
Intersil
Quantity:
2 000
Part Number:
ISL6742AAZA-T
Manufacturer:
INTERSIL
Quantity:
20 000
Electrical Specifications
NOTES:
CT Valley Voltage
CT Peak Voltage
CT Pk-Pk Voltage
RTD Voltage
OUTPUT
High Level Output Voltage (VOH)
Low Level Output Voltage (VOL)
Rise Time
Fall Time
UVLO Output Voltage Clamp
Output Delay/Advance Range
Delay Control Voltage Range
VADJ Delay Time
THERMAL PROTECTION
Thermal Shutdown
Thermal Shutdown Clear
Hysteresis, Internal Protection
3. Limits established by characterization and are not production tested.
4. This is the maximum duty cycle achievable using the specified values of RTD and CT. Larger or smaller maximum duty cycles may be obtained
5. Adjust VDD below the UVLO stop threshold prior to setting at 7V.
6. When OUTx is delayed relative to OUTLxN (VADJ < 2.425V), the delay duration as set by VADJ should not exceed 90% of the CT discharge time
OUTAN/OUTBN Relative to OUTA/OUTB
OUTAN/OUTBN Relative to OUTA/OUTB
using other values for these components. See Equations 1 through 3.
(deadtime) as determined by CT and RTD.
PARAMETER
7
Recommended operating conditions unless otherwise noted. Refer to “Functional Block Diagram” on page 2,
“Typical Application - Telecom Primary Side Control Half-Bridge Converter with Synchronous Rectification” on
page 3 and “Typical Application - High Voltage Input Secondary Side Control Full-Bridge Converter” on page 4.
9V < VDD < 20V, RTD = 10.0kΩ, CT = 470pF, T
Parameters with MIN and/or MAX limits are 100% tested at +25°C, unless otherwise specified. Temperature
limits established by characterization and are not production tested. (Continued)
Static Threshold
Static Threshold
Static Value
I
I
C
C
VDD = 7V, I
V
V
V
OUTxN Delayed
OUTx Delayed
T
T
(Note 3)
(Note 3)
(Note 3)
OUT
OUT
A
ADJ
ADJ
ADJ
A
OUT
OUT
= +25°C (OUTxN Delayed)
= +25°C (OUTx Delayed) (Note 6)
VADJ = 0
VADJ = 0.5V
VADJ = 1.0V
VADJ = 1.5V
VADJ = 2.0V
VADJ = VREF
VADJ = VREF - 0.5V
VADJ = VREF - 1.0V
VADJ = VREF - 1.5V
VADJ = VREF - 2.0V
= -10mA, VDD - VOH
= 10mA, VOL - GND
= 2.50V (Note 3)
< 2.425V
> 2.575V
= 220pF, VDD = 15V (Note 3)
= 220pF, VDD = 15V (Note 3)
TEST CONDITIONS
LOAD
ISL6742
= 1mA (Note 5)
A
= -40°C to +105°C, Typical values are at T
2.575
0.75
2.75
1.92
1.97
MIN
280
280
130
115
-40
40
92
61
48
41
86
59
47
41
0
-
-
-
-
-
-
-
TYP
0.80
2.80
2.00
2.00
300
105
300
100
140
125
110
0.5
0.5
90
70
55
50
68
55
48
15
-
-
-
-
-
-
5.000
2.425
MAX
2.05
-300
0.88
2.88
2.03
1.25
200
150
300
320
320
150
135
118
114
1.0
1.0
80
65
58
77
62
55
3
-
A
= +25°C.
October 31, 2008
UNITS
°C
°C
°C
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
FN9183.2
V
V
V
V
V
V
V
V
V

Related parts for ISL6742AAZA