ADUM3400CRWZ Analog Devices Inc, ADUM3400CRWZ Datasheet - Page 13

no-image

ADUM3400CRWZ

Manufacturer Part Number
ADUM3400CRWZ
Description
IC DIGITAL ISOLATOR 4CH 16-SOIC
Manufacturer
Analog Devices Inc
Series
iCoupler®r
Datasheet

Specifications of ADUM3400CRWZ

Propagation Delay
27ns
Inputs - Side 1/side 2
4/0
Number Of Channels
4
Isolation Rating
2500Vrms
Voltage - Supply
2.7 V ~ 5.5 V
Data Rate
120Mbps
Output Type
Logic
Package / Case
16-SOIC (0.300", 7.5mm Width)
Operating Temperature
-40°C ~ 105°C
No. Of Channels
4
Supply Current
72mA
Supply Voltage Range
2.7V To 5.5V
Digital Ic Case Style
SOIC
No. Of Pins
16
Operating Temperature Range
-40°C To +105°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUM3400CRWZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
ADUM3400CRWZ
Quantity:
65
Part Number:
ADUM3400CRWZ-RL
Manufacturer:
AD
Quantity:
3 399
Part Number:
ADUM3400CRWZ-RL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS
These isolators are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by
protective circuits. The * marking on packages denotes DIN V VDE V 0884-10 approval.
Table 7.
Description
Installation Classification per DIN VDE 0110
Climatic Classification
Pollution Degree per DIN VDE 0110, Table 1
Maximum Working Insulation Voltage
Input-to-Output Test Voltage, Method B1
Input-to-Output Test Voltage, Method A
Highest Allowable Overvoltage
Safety-Limiting Values
Insulation Resistance at T
Figure 4. Thermal Derating Curve, Dependence of Safety-Limiting Values
For Rated Mains Voltage ≤ 150 V rms
For Rated Mains Voltage ≤ 300 V rms
For Rated Mains Voltage ≤ 400 V rms
After Environmental Tests Subgroup 1
Case Temperature
Side 1 Current
Side 2 Current
After Input and/or Safety Test Subgroup 2 and Subgroup 3
350
300
250
200
150
100
50
0
0
with Case Temperature per DIN V VDE V 0884-10
50
CASE TEMPERATURE (°C)
SIDE #1
S
SIDE #2
100
150
200
Rev. A | Page 13 of 24
Conditions
V
t
V
partial discharge < 5 pC
V
partial discharge < 5 pC
Transient overvoltage, t
Maximum value allowed in the
event of a failure (see Figure 4)
V
m
IORM
IORM
IORM
IO
= 1 sec, partial discharge < 5 pC
= 500 V
× 1.875 = V
× 1.6 = V
× 1.2 = V
RECOMMENDED OPERATING CONDITIONS
Table 8.
Parameter
Operating Temperature Range (T
Supply Voltages (V
Input Signal Rise and Fall Times
1
PR
PR
All voltages are relative to their respective ground. See the DC Correctness
and Magnetic Field Immunity section for information on immunity to
external magnetic fields.
PR
, t
, t
, 100% production test,
m
m
= 60 sec,
= 60 sec,
TR
ADuM3400/ADuM3401/ADuM3402
= 10 seconds
DD1
, V
DD2
)
1
Symbol
V
V
V
V
T
I
I
R
S1
S2
S
S
IORM
PR
PR
TR
A
)
Characteristic
I to IV
I to III
I to II
40/105/21
2
560
1050
896
672
4000
150
265
335
>10
Rating
−40°C to +105°C
2.7 V to 5.5 V
1.0 ms
9
Unit
V peak
V peak
V peak
V peak
V peak
°C
mA
mA
Ω

Related parts for ADUM3400CRWZ