Specifications of ADUM3400CRWZ

Propagation Delay
27ns
Inputs - Side 1/side 2
4/0
Number Of Channels
4
Isolation Rating
2500Vrms
Voltage - Supply
2.7 V ~ 5.5 V
Data Rate
120Mbps
Output Type
Logic
Package / Case
16-SOIC (0.300", 7.5mm Width)
Operating Temperature
-40°C ~ 105°C
No. Of Channels
4
Supply Current
72mA
Supply Voltage Range
2.7V To 5.5V
Digital Ic Case Style
SOIC
No. Of Pins
16
Operating Temperature Range
-40°C To +105°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUM3400CRWZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
ADUM3400CRWZ
Quantity:
65
Part Number:
ADUM3400CRWZ-RL
Manufacturer:
AD
Quantity:
3 399
Part Number:
ADUM3400CRWZ-RL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ADuM3400/ADuM3401/ADuM3402
To calculate the total I
currents for each input and output channel corresponding to
V
per-channel input supply current as a function of the data rate.
Figure 9 and Figure 10 provide the per-channel supply output
current as a function of the data rate for an unloaded output
condition and for a 15 pF output condition, respectively. Figure 11
through Figure 15 provide the total V
as a function of the data rate for ADuM3400/ADuM3401/
ADuM3402 channel configurations.
INSULATION LIFETIME
All insulation structures eventually break down when subjected
to voltage stress over a sufficiently long period. The rate of
insulation degradation is dependent on the characteristics of
the voltage waveform applied across the insulation. In addition
to the testing performed by the regulatory agencies, Analog
Devices carries out an extensive set of evaluations to determine
the lifetime of the insulation structure within the ADuM340x.
Analog Devices performs accelerated life testing using voltage
levels higher than the rated continuous working voltage.
Acceleration factors for several operating conditions are
determined. These factors allow calculation of the time to
failure at the actual working voltage. The values shown in
Figure 21 summarize the peak voltage for 50 years of service life
for a bipolar ac operating condition, and the maximum
CSA/VDE approved working voltages. In many cases, the
approved working voltage is higher than the 50-year service life
voltage. Operation at these high working voltages can lead to
shortened insulation life in some cases.
The insulation lifetime of the ADuM340x depends on the
voltage waveform type imposed across the isolation barrier. The
iCoupler insulation structure degrades at different rates
depending on whether the waveform is bipolar ac, unipolar ac,
or dc. Figure 21, Figure 22, and Figure 23 illustrate these
different isolation voltage waveforms.
Bipolar ac voltage is the most stringent environment. The goal
of a 50-year operating lifetime under the ac bipolar condition
determines the recommended maximum working voltage of
Analog Devices.
DD1
and V
DD2
are calculated and totaled. Figure 8 provides the
DD1
and I
DD2
supply current, the supply
DD1
and V
DD2
supply current
Rev. A | Page 22 of 24
In the case of unipolar ac or dc voltage, the stress on the
insulation is significantly lower, which allows operation at
higher working voltages while still achieving a 50-year service
life. The working voltages listed in Table 10 can be applied while
maintaining the 50-year minimum lifetime provided the voltage
conforms to either the unipolar ac or dc voltage cases. Any cross
insulation voltage waveform that does not conform to Figure 22 or
Figure 23 should be treated as a bipolar ac waveform and its
peak voltage should be limited to the 50-year lifetime voltage
value listed in Table 10.
Note that the voltage presented in Figure 22 is shown as
sinusoidal for illustration purposes only. It is meant to represent
any voltage waveform varying between 0 V and some limiting
value. The limiting value can be positive or negative, but the
voltage cannot cross 0 V.
RATED PEAK VOLTAGE
RATED PEAK VOLTAGE
RATED PEAK VOLTAGE
0V
0V
0V
Figure 22. Unipolar AC Waveform
Figure 21. Bipolar AC Waveform