KP-FSD3 Panduit Corp, KP-FSD3 Datasheet - Page 797

KIT FERRULE INS DIN AWG12-6

KP-FSD3

Manufacturer Part Number
KP-FSD3
Description
KIT FERRULE INS DIN AWG12-6
Manufacturer
Panduit Corp
Series
Pan-Term®r
Type
Ferrule Kitr
Datasheet

Specifications of KP-FSD3

Kit Type
Ferrule - Wire End
Values
100 pcs - Assorted Insulated 12 ~ 6 AWG Ferrules
Kit Contents
50 Pieces Of FSD81-10, 20 Pieces Each Of FSD82-12 And FSD83-12, 10 Pieces Of FSD84-12
Mounting Method
Crimp
Where Used
To terminate stranded wire for insertion into terminal blocks
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
• For copper-to-copper tapping, splicing or pigtailing
• Wide wire range-taking capability minimizes inventory
• Color-coded for proper crimp die selection
• Ribbed design provides high strength
For Copper Code Stranded Connections
Type CTAPF
See pages D3.92 and D3.93 for tool and die information.
*CTAPF10-16-C available with square, not flared ends.
All parts available in tin-plated; add TP before packaging code – example: CTAPF6-12TP-C.
^Note: CTAPF parts are UL Listed and CSA Certified with AWG wire only.
‡CSA Certified for grounding and bonding.
Part Number
CTAPF10-16-C*
CTAPF8-12-C‡
CTAPF6-12-C‡
CTAPF4-12-C‡
CTAPF3-12-C‡
CTAPF2-12-C‡
CTAPF1-12-C
CTAPF1/0-12-L
CTAPF2/0-12-Q
CTAPF3/0-12-Q
requirements
Code Conductor, Thin Wall, CTAP
AWG Run (mm
#5, #4 AWG
#5, #4 AWG
#14 AWG
#12 AWG
#10 AWG
#10 AWG
1/0 AWG
1/0 AWG
2/0 AWG
1/0 AWG
2/0 AWG
3/0 AWG
#8 AWG
#8 AWG
#6 AWG
#6 AWG
#3 AWG
#4 AWG
#3 AWG
#2 AWG
#3 AWG
#2 AWG
#1 AWG
#2 AWG
#1 AWG
#1 AWG
(16, 25)
(16, 25)
(10.0)
(10.0)
(16.0)
(2.5)
(4.0)
(6.0)
(6.0)
(16)
(25)
(25)
(25)
(35)
(25)
(35)
(35)
(35)
(35)
(50)
(35)
(50)
(70)
(50)
(70)
(95)
Copper Conductor Size
2
)
AWG Tap (mm
#16 – #14 AWG
#16 – #12 AWG
#12 – #10 AWG
#10 – #8 AWG
#12 – #8 AWG
#12 – #6 AWG
#12 – #6 AWG
#12 – #5 AWG
#12 – #4 AWG
#12 – #3 AWG
#12 – #2 AWG
#1 – 1/0 AWG
#8 – #6 AWG
#6 – #5 AWG
#4 – #3 AWG
#5 – #4 AWG
#4 – #2 AWG
#4 – #3 AWG
#2 – #1 AWG
#3 – #2 AWG
#2 – #1 AWG
(6.0 – 10.0)
(1.5 – 2.5)
(1.5 – 4.0)
(4.0 – 6.0)
#14 AWG
#10 AWG
#12 AWG
(10 – 16)
(16 – 25)
(25 – 35)
(25 – 35)
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
#4 AWG
#5 AWG
(4 – 10)
(4 – 16)
(4 – 16)
(4 – 16)
(4 – 25)
(4 – 35)
(4 – 35)
(2.5)
(6.0)
(4.0)
(16)
(25)
(16)
(25)
(25)
(35)
(50)
(35)
2
)
ELECTRICAL SOLUTIONS
Number of
Ribs
0
0
0
1
1
1
2
2
2
2
T
• Made from high conductivity wrought copper
• UL Listed and CSA Certified to 600 V and temperature rated to
(10.4)
(17.0)
(17.0)
(31.8)
(31.8)
(31.8)
(46.2)
(46.2)
(46.2)
(46.2)
0.41
0.67
0.67
1.25
1.25
1.25
1.82
1.82
1.82
1.82
90°C when crimped with Panduit and specified competitor crimping
tools and dies^
L
Figure Dimensions
V
0.06
(1.5)
0.07
(1.8)
0.07
(1.8)
0.07
(1.8)
0.08
(2.0)
0.08
(2.0)
0.08
(2.0)
0.09
(2.3)
0.09
(2.3)
0.09
(2.3)
T
In. (mm)
(10.2)
(11.7)
(13.0)
(14.5)
(16.0)
(18.0)
(20.6)
(4.8)
(6.6)
(8.1)
.19
.26
.32
.40
.46
.51
.57
.63
.71
.81
L
V
(10.2)
(10.7)
(12.2)
(14.0)
0.13
(3.3)
0.19
(4.8)
0.24
(6.1)
0.28
(7.1)
0.31
(7.9)
0.33
(8.4)
0.40
0.42
0.48
0.55
Q
Q
Panduit Color
Orange
Purple
Brown
Green
Yellow
Code
Black
Blue
Gray
Red
Pink
Wire Strip
In. (mm)
Length
1 5/16
1 5/16
1 5/16
(12.7)
(17.5)
(17.5)
(33.3)
(33.3)
(33.3)
(47.6)
(47.6)
(47.6)
(47.6)
11/16
11/16
1 7/8
1 7/8
1 7/8
1 7/8
1/2
Pkg.
Std.
Qty.
100
100
100
100
100
100
100
50
25
25
D3.11
Management
Identification
Accessories
Connectors
Connectors
Grounding
Pre-Printed
& Write-On
Protection
Permanent
Solutions
Cable Ties
Terminals
Lockout/
Overview
Steel Ties
& Safety
Stainless
Raceway
Abrasion
Labeling
Systems
Surface
Markers
Tagout
System
Wiring
Labels
Power
Cable
Cable
Index
Duct
E5.
B1.
B2.
B3.
D1.
D2.
D3.
C1.
C2.
C3.
C4.
E1.
E2.
E3.
E4.
A.
F.