KP-FSD3 Panduit Corp, KP-FSD3 Datasheet - Page 801

KIT FERRULE INS DIN AWG12-6

KP-FSD3

Manufacturer Part Number
KP-FSD3
Description
KIT FERRULE INS DIN AWG12-6
Manufacturer
Panduit Corp
Series
Pan-Term®r
Type
Ferrule Kitr
Datasheet

Specifications of KP-FSD3

Kit Type
Ferrule - Wire End
Values
100 pcs - Assorted Insulated 12 ~ 6 AWG Ferrules
Kit Contents
50 Pieces Of FSD81-10, 20 Pieces Each Of FSD82-12 And FSD83-12, 10 Pieces Of FSD84-12
Mounting Method
Crimp
Where Used
To terminate stranded wire for insertion into terminal blocks
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Type HTWC
• Include all components to make a complete HTAP and cover
• Each HTCT HTAP designed to terminate a wide range of copper
• HTAPs incorporate a unique slotted design that allows for quick
See pages D3.13 – D3.14 for more information on HTAPs and clear covers, including tap sizes and locations.
^Note: HTCT parts are UL Listed and CSA Certified with AWG wire only.
Part Number
HTWC6X-6X-1
HTWC2-2-1
HTWC250-2-1
HTWC250-250-1
installation: HTCT HTAP, matching CLRCVR clear cover,
and cable ties
code and flex conductor combinations to accommodate a variety
of applications
and easy installation using supplied Panduit cable ties; saves time
and cost
RUN
TAP 1
H
W
Code/Flex Conductor HTAP Kit
L
HTCT250-250-1
HTCT6X-6X-1
HTCT250-2-1
HTCT2-2-1
Part No.
HTAP
Components
TAP 2
Clear Cover
CLRCVR1-1
CLRCVR2-1
CLRCVR3-1
CLRCVR3-1
RUN
TAP 1
Part No.
H
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
W
TAP 3
Wire Strand
L
Code
Code
Code
Code
Type
Flex
Flex
Flex
Flex
ELECTRICAL SOLUTIONS
#6 – #14 AWG
#6 – #10 AWG
250 kcmil – #2
250 kcmil – #2
4/0 – #2 AWG
4/0 – #2 AWG
#2 – #6 AWG
#2 – #8 AWG
(120 – 35)
(120 – 35)
(10 – 2.5)
(10 – 2.5)
STR/SOL
(25 – 16)
(25 – 10)
(95 – 35)
(95 – 35)
• Matching clear covers are made from high impact plastic and
• Clear covers have a UL 94 V-0 flame rating and an oxygen index
• UL Listed and CSA Certified for applications up to 600 V when
• See page D3.33 for detailed installation instructions
AWG
AWG
Run
Copper Conductor Size Range AWG (mm
provide high impact strength and 360° viewing of installed HTAP
of 28 providing self-extinguishing, flame retardant properties
crimped with Panduit and specified competitor crimping tools
and Panduit crimping dies^
RUN
TAP 1
H
W
#6 – #14 AWG
#6 – #14 AWG
250 kcmil – #2
4/0 – #2 AWG
#2 – #6 AWG
#2 – #8 AWG
#2 – #6 AWG
#2 – #8 AWG
(120 – 35)
(10 – 2.5)
(10 – 2.5)
STR/SOL
STR/SOL
(25 – 16)
(25 – 10)
(25 – 16)
(25 – 10)
(95 – 35)
Tap 1
AWG
TAP 2
L
#8 – #14 AWG
#8 – #14 AWG
#8 – #14 AWG
#8 – #14 AWG
(6 – 2.5)
(6 – 2.5)
(6 – 2.5)
(6 – 2.5)
Tap 2
2
)
RUN
H
#8 – #14 AWG
#8 – #14 AWG
W
(6 – 2.5)
(6 – 2.5)
Tap 3
TAP 1
L
Pkg.
Std.
Qty.
1
1
1
1
D3.15
Management
Identification
Accessories
Connectors
Connectors
Grounding
Pre-Printed
& Write-On
Protection
Permanent
Solutions
Cable Ties
Terminals
Lockout/
Overview
Steel Ties
& Safety
Stainless
Raceway
Abrasion
Labeling
Systems
Surface
Markers
Tagout
System
Wiring
Labels
Power
Cable
Cable
Index
Duct
E5.
B1.
B2.
B3.
D1.
D2.
D3.
C1.
C2.
C3.
C4.
E1.
E2.
E3.
E4.
A.
F.