JW030F1-M Lineage Power, JW030F1-M Datasheet - Page 14

no-image

JW030F1-M

Manufacturer Part Number
JW030F1-M
Description
CONVERT DC/DC 3.3V 21.5W OUT
Manufacturer
Lineage Power
Series
JW030r
Type
Isolated with Remote On/Offr
Datasheet

Specifications of JW030F1-M

Output
3.3V
Number Of Outputs
1
Power (watts)
30W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module
1st Output
3.3 VDC @ 6.5A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
21.5W
Operating Temperature
-40°C ~ 100°C
Efficiency
75%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
JW030F1-M
Manufacturer:
LUCENT
Quantity:
489
36 Vdc to 75 Vdc Inputs; 30 W
Thermal Considerations
The JW030-Series Power Modules are designed to operate in a variety of thermal environments. As with any elec-
tronic component, sufficient cooling must be provided to help ensure reliable operation. Heat-dissipating compo-
nents inside the module are thermally coupled to the case to enable heat removal by conduction, convection, and
radiation to the surrounding environment.
The thermal data presented is based on measurements taken in a wind tunnel. The test setup shown in Figure 27
was used to collect data for Figure 34.
The graphs in Figures 28 through 33 provide general guidelines for use. Actual performance can vary depending
on the particular application environment. The maximum case temperature of 100 °C must not be exceeded.
Note: Dimensions are in millimeters and (inches).
Basic Thermal Performance
The JW030-Series Power Modules are constructed with a specially designed, heat spreading enclosure. As a
result, full-load operation in natural convection at 50 °C can be achieved without the use of an external heat sink.
Higher ambient temperatures can be sustained by increasing the airflow or by adding a heat sink. As stated, this
data is based on a maximum case temperature of 100 °C and measured in the test configuration shown in
Figure 27.
14
CONNECTORS TO
SUPPLIES, AND
LOADS, POWER
6.35 (0.25) TALL
DATALOGGER,
101.6
(4.00)
Figure 27. Thermal Test Setup
203.2 (8.00)
AIRFLOW
MEASURE CASE
TEMPERATURE (T
CENTER OF UNIT
(3.00)
76.2
C
) AT
203.2
(8.00)
FLOW
AIR-
AIR VELOCITY
AND AMBIENT
TEMPERATURE
MEASURED
BELOW THE
MODULE
19.1 (0.75)
12.7 (0.50)
WIND TUNNEL
WALL
March 26, 2008
Lineage Power
8-1046(C)

Related parts for JW030F1-M