JW075A1 Lineage Power, JW075A1 Datasheet - Page 13

no-image

JW075A1

Manufacturer Part Number
JW075A1
Description
CONVERTER DC/DC 5V 75W OUT
Manufacturer
Lineage Power
Series
JW075r
Type
Isolated with Remote On/Offr
Datasheet

Specifications of JW075A1

Output
5V
Number Of Outputs
1
Power (watts)
75W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module
1st Output
5 VDC @ 15A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
75W
Operating Temperature
-40°C ~ 100°C
Efficiency
84%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
JW075A1
Manufacturer:
LUCENT
Quantity:
27
Part Number:
JW075A1
Manufacturer:
MOLEX
Quantity:
220
Part Number:
JW075A1
Quantity:
55
Part Number:
JW075A1-53
Manufacturer:
POWEREX
Quantity:
1 000
Part Number:
JW075A1-E
Manufacturer:
LUCENT
Quantity:
27
Part Number:
JW075A1-E
Manufacturer:
LUCENT
Quantity:
387
Data Sheet
April 2008
Thermal Considerations
Introduction
The power modules operate in a variety of thermal
environments; however, sufficient cooling should be
provided to help ensure reliable operation of the unit.
Heat-dissipating components inside the unit are ther-
mally coupled to the case. Heat is removed by conduc-
tion, convection, and radiation to the surrounding
environment. Proper cooling can be verified by mea-
suring the case temperature. Peak temperature (T
occurs at the position indicated in Figure 26.
Note: Top view, pin locations are for reference only.
Figure 26. Case Temperature Measurement
The temperature at this location should not exceed
100 °C. The output power of the module should not
exceed the rated power for the module as listed in the
Ordering Information table.
Although the maximum case temperature of the power
modules is 100 °C, you can limit this temperature to a
lower value for extremely high reliability.
For additional information on these modules, refer to
the Thermal Management JC-, JFC-, JW-, and JFW-
Series 50 W to 150 W Board-Mounted Power Modules
Technical Note
(TN97-008EPS).
Lineage Power
7.6 (0.3)
Measurements shown in millimeters and (inches).
Location
V
ON/OFF
CASE
V
I
I
38.0 (1.50)
(+)
(–)
dc-dc Converters; 36 to 75 Vdc Input, 5 Vdc Output; 50 W to 150 W
+ SEN
– SEN
V
V
TRIM
O
O
(+)
(–)
MEASURE CASE
TEMPERATURE HERE
JW050A, JW075A, JW100A, JW150A Power Modules:
8-716 (C).f
C
)
Heat Transfer Without Heat Sinks
Increasing airflow over the module enhances the heat
transfer via convection. Figure 27 shows the maximum
power that can be dissipated by the module without
exceeding the maximum case temperature versus local
ambient temperature (T
through 4 m/s (800 ft./min.).
Note that the natural convection condition was mea-
sured at 0.05 m/s to 0.1 m/s (10 ft./min. to 20 ft./min.);
however, systems in which these power modules may
be used typically generate natural convection airflow
rates of 0.3 m/s (60 ft./min.) due to other heat dissipat-
ing components in the system. The use of Figure 27 is
shown in the following example.
Example
What is the minimum airflow necessary for a JW100A
operating at V
maximum ambient temperature of 40 °C?
Solution
Given: V
Determine P
Determine airflow (v) (Use Figure 27.):
Figure 27. Forced Convection Power Derating with
35
30
25
20
15
10
5
0
0
I
T
P
v = 2.0 m/s (400 ft./min.)
O
A
I
D
= 54 V
= 20 A
0.1 m/s (NAT. CONV.)
= 40 °C
No Heat Sink; Either Orientation
= 17 W
10
D
I
LOCAL AMBIENT TEMPERATURE, T
(Use Figure 30.):
= 54 V, an output current of 20 A, and a
20
(20 ft./min.)
30
A
) for natural convection
40
50
60
4.0 m/s (800 ft./min.)
3.5 m/s (700 ft./min.)
3.0 m/s (600 ft./min.)
2.5 m/s (500 ft./min.)
2.0 m/s (400 ft./min.)
1.5 m/s (300 ft./min.)
1.0 m/s (200 ft./min.)
0.5 m/s (100 ft./min.)
70
A
80
( C)
8-1150 (C).a
90
13
100