ATM030A0X3-SRHZ Lineage Power, ATM030A0X3-SRHZ Datasheet - Page 11

no-image

ATM030A0X3-SRHZ

Manufacturer Part Number
ATM030A0X3-SRHZ
Description
CONVERTER DC-DC 0.8 2VDC @ 30A
Manufacturer
Lineage Power
Series
Austin MegaLynx™r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of ATM030A0X3-SRHZ

Output
0.8 ~ 2V
Number Of Outputs
1
Power (watts)
60W
Mounting Type
Surface Mount
Voltage - Input
2.7 ~ 4V
Package / Case
5-SMD Module
1st Output
0.8 ~ 2 VDC @ 30A
Size / Dimension
1.30" L x 0.36" W x 0.53" H (33mm x 9.1mm x 13.5mm)
Power (watts) - Rated
60W
Operating Temperature
-40°C ~ 85°C
Efficiency
92%
Approvals
CSA, EN, UL, VDE
Output Power
60 W
Input Voltage Range
2.7 V to 4 V
Output Voltage (channel 1)
0.8 V to 2 V
Output Current (channel 1)
30 A
Package / Case Size
SMD
Output Type
Non-Isolated
Output Voltage
0.8 V to 2 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Q5188004
Data Sheet
October 21, 2009
Feature Descriptions
Remote On/Off
The ATM030 SMT power modules feature a On/Off
pin for remote On/Off operation. If not using the
On/Off pin, connect the pin to ground (the module
will be ON). The On/Off signal (V
to ground. Circuit configuration for remote On/Off
operation of the module using the On/Off pin is
shown in Figure 29.
During a Logic High on the On/Off pin (transistor Q1
is OFF), the module remains OFF. The external
resistor R
minimum on the On/Off pin to ensure that the
module is OFF when transistor Qx is in the OFF
state. A suitable values for R
During Logic-Low when Q
module is turned ON.
The On/Off pin can also be used to synchronize the
output voltage start-up and shutdown of multiple
modules in parallel. By connecting On/Off pins of
multiple modules, the output start-up can be
synchronized (please refer to characterization
curves). When On/Off pins are connected together,
all modules will shutdown if any one of the modules
gets disabled due to undervoltage lockout or over
temperature protection
Remote Sense
The ATM030 power modules have a Remote Sense
feature to minimize the effects of distribution losses
by regulating the voltage at the Remote Sense pin
(See Figure 30). The voltage between the Sense
pin and Vo pin must not exceed 0.5V.
LINEAGE
Figure 29. Remote On/Off Implementation
using ON/OFF .
ON/OFF
VIN+
GN D
X
POWER
should be chosen to maintain 2.5V
R1
V
Q1
I
ON/OFF
ON/OFF
+
_
.
1K
10K
X
is turned ON, the
X
MODULE
is 3K for 5Vin.
on/off
Austin MegaLynx
) is referenced
Therm al SD
PW M Enable
2.7 – 4.0Vdc input; 0.8 to 2.0Vdc Output; 30A output current
100K
TM
The amount of power delivered by the module is
defined as the output voltage multiplied by the
output current (Vo x Io). When using Remote
Sense, the output voltage of the module can
increase, which if the same output is maintained,
increases the power output by the module. Make
sure that the maximum output power of the module
remains at or below the maximum rated power.
When the Remote Sense feature is not being used,
connect the Remote Sense pin to output of the
module.
Over Current Protection
To provide protection in a fault (output overload)
condition, the unit is equipped with internal
current-limiting circuitry and can endure current
limiting continuously. At the point of current-limit
inception, the unit enters hiccup mode. The unit
operates normally once the output current is
brought back into its specified range. The average
output current during hiccup is 10% I
Over Temperature Protection
To provide protection in a fault condition, the unit is
equipped with a thermal shutdown circuit. The unit
will shutdown if the overtemperature threshold of
125
T
guarantee that the unit will survive temperatures
beyond its rating. Once the unit goes into thermal
shutdown it will then wait to cool before attempting
to restart.
Input Under Voltage Lockout
At input voltages below the input undervoltage
lockout limit, the module operation is disabled. The
module will begin to operate at an input voltage
above the undervoltage lockout turn-on threshold.
SMT: Non-Isolated DC-DC Power Modules:
ref
Figure 30. Effective Circuit Configuration for
Remote Sense operation.
. The thermal shutdown is not intended as a
o
C is exceeded at the thermal reference point
R
R
d istrib u tio n
d istrib u tio n
R
R
c o n ta c t
c o n ta c t
V
C O M
IN
(+ )
S e ns e
C O M
V
O
O, max
R
R
c o n ta c t
c o n ta c t
.
R
R
d istrib u tio n
d istrib u tio n
R
L O A D
11

Related parts for ATM030A0X3-SRHZ