DS1200-3-002 Emerson Network Power, DS1200-3-002 Datasheet - Page 33

no-image

DS1200-3-002

Manufacturer Part Number
DS1200-3-002
Description
POWER SUPPLY AC/DC 12V 1200W
Manufacturer
Emerson Network Power
Series
DS1200r
Datasheets

Specifications of DS1200-3-002

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
1200W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
180 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 100A
Size / Dimension
11" L x 3.2" W x 1.57" H (279.4mm x 81.3mm x 39.9mm)
Power (watts) - Rated
1200W
Operating Temperature
-10°C ~ 50°C
Efficiency
91%
Approvals
CB, CE, cUL, EN, NEMKO, UL
Line Regulation
±5%
Load Regulation
±5%
Input Voltage
90 to 264V
Output Voltage
12V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
-10C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1271
Power Supply Status Register, PMBus
Power supply status monitoring can be done via the PMBus
explanation of functions is given below:
• OCP
• UVP
• OVP
• FAN_OK
• AC_OK
• TEMP_OK
• V
• V
SB
O
BIT 7
OCP
OK
OK
Normal / 12V OFF
Normal / 12V ON
Over Temp Fault
Low AC / No AC
Signal Name
Fan Fault
- Over Current Protection
- This bit will be set when the power supply outputs have been disabled due to an over current event.
- Under Voltage Protection
- This bit will be set when the power supply outputs have been disabled due to an under voltage event.
- Over Voltage Protection
- This bit will be set when the power supply outputs have been disabled due to an over voltage event.
- Fan Status
- Any abnormalities on the fan will clear this bit. Normal fan operation, this is set to high.
- AC line voltage status
- This bit is an image of the AC_OK signal coming out the power supply to the system. A logic HIGH, if
- Over temperature status.
- A logic HIGH, when the power supply is operating within allowable temperature range. This bit will be
- StandBy Output (V
- This bit is set when the StandBy Output (V
- Main Output (V
- This bit is set when the Main Output (V
the input voltage is within allowable limits. This bit will be cleared when the power supply line voltage is
past the trip limit.
cleared when the power supply temperature is past the trip limit.
V
voltage is out of regulation.
OCP
UVP
OVP
SB
BIT 6
UVP
voltage is out of regulation.
O
) status.
BIT 5
OVP
SB
) status.
FAN_OK
TM
Status Register Code
BIT 4
Register 0xEFh
Code (Binary)
O
00011111
00011110
10011111
01011110
00111110
00001110
00010100
00011010
) is within regulation limits. This bit will be cleared when the V
TM
SB
) is within regulation limits. This bit will be cleared when the
register 0xEFh or as I/O expander Detailed
AC_OK
BIT 3
TEMP_OK
BIT 2
V
Code (Hex)
BIT 1
SB
OK
1E
9E
5E
3E
0E
1A
1F
14
Rev.10.03.30_#0.1
DS1200-3 Series
V
BIT 0
O
OK
Page 33