EVAL-AD7150EBZ Analog Devices Inc, EVAL-AD7150EBZ Datasheet - Page 15

BOARD EVAL FOR AD7150

EVAL-AD7150EBZ

Manufacturer Part Number
EVAL-AD7150EBZ
Description
BOARD EVAL FOR AD7150
Manufacturer
Analog Devices Inc
Datasheet

Specifications of EVAL-AD7150EBZ

Sensor Type
Touch, Capacitive
Interface
I²C
Voltage - Supply
2.7 V ~ 3.6 V
Embedded
No
Utilized Ic / Part
AD7150
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Sensitivity
-
Sensing Range
-
Lead Free Status / Rohs Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EVAL-AD7150EBZ
Manufacturer:
Analog Devices Inc
Quantity:
135
STATUS REGISTER
Address Pointer 0x00
8 Bits, Read-Only, Default Value 0x53 Before Conversion, 0x54 After Conversion
The status register indicates the status of the part. The register can be read via the 2-wire serial interface to query the status of the outputs,
check the CDC finished conversion, and check whether the CAPDAC has been changed by the autoCAPDAC function.
Table 6. Status Register Bit Map
Bit
Mnemonic
Default
Table 7. Status Register Bit Descriptions
Bit
7
6
5
4
3
2
1
0
Mnemonic
PwrDown
DacStep2
OUT2
DacStep1
OUT1
C1/C2
RDY2
RDY1
Description
PwrDown = 1 indicates that the part is in a power-down mode or that the part V
monitor threshold voltage.
DacStep2 = 0 indicates that the Ch2 CAPDAC value was changed after the last CDC conversion as part of the
AutoDac function. The bit value is updated after each finished CDC conversion on this channel.
OUT2 = 1 indicates that the Ch2 data (CIN2 capacitance) crossed the threshold, according to the selected
comparator mode of operation. The bit value is updated after each finished CDC conversion on this channel.
DacStep1 = 0 indicates that the Ch1 CAPDAC value was changed during the last conversion as part of the
AutoDac function. The bit value is updated after each finished CDC conversion on this channel.
OUT1 = 1 indicates that the Ch1 data (CIN1 capacitance) crossed the threshold, according to the selected
comparator mode of operation. The bit value is updated after each finished CDC conversion on this channel.
The C1/C2 = 0 indicates that the last finished CDC conversion was on Channel 1.
The C1/C2 = 1 indicates that the last finished CDC conversion was on Channel 2.
RDY2 = 0 indicates a finished CDC conversion on Ch2. The bit is reset back to 1 when the Ch2 data register is
read via the serial interface or after the part reset or power-up.
RDY1= 0 indicates a finished CDC conversion on Ch1. The bit is reset back to 1 when the Ch1 data register is
read via serial interface or after the part reset or power-up.
PwrDown
Bit 7
0
DacStep2
Bit 6
1
OUT2
Bit 5
Rev. 0 | Page 15 of 28
0
DacStep1
Bit 4
1
OUT1
Bit 3
0
C1/C2
Bit 2
0
DD
is below the power supply
RDY2
Bit 1
1
AD7150
RDY1
Bit 0
1

Related parts for EVAL-AD7150EBZ