EVAL-AD7150EBZ Analog Devices Inc, EVAL-AD7150EBZ Datasheet - Page 17

BOARD EVAL FOR AD7150

EVAL-AD7150EBZ

Manufacturer Part Number
EVAL-AD7150EBZ
Description
BOARD EVAL FOR AD7150
Manufacturer
Analog Devices Inc
Datasheet

Specifications of EVAL-AD7150EBZ

Sensor Type
Touch, Capacitive
Interface
I²C
Voltage - Supply
2.7 V ~ 3.6 V
Embedded
No
Utilized Ic / Part
AD7150
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Sensitivity
-
Sensing Range
-
Lead Free Status / Rohs Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EVAL-AD7150EBZ
Manufacturer:
Analog Devices Inc
Quantity:
135
TIMEOUT REGISTERS
Ch1 Address Pointer 0x0A
Ch2 Address Pointer 0x0D
8 Bits, Read/Write, Factory Preset 0x86
Table 9. Timeout Register Bit Map
Bit
Mnemonic
Default
These registers set timeouts for the adaptive threshold mode.
The approaching timeout starts when the CDC data crosses the
data average ± sensitivity band toward the threshold, according
to the selected positive, negative, or window threshold mode.
The approaching timeout elapses after the number of conversion
cycles equals 2
most significant bits of the timeout register.
The receding timeout starts when the CDC data crosses the
data average ± sensitivity band away from the threshold,
according to the selected positive or negative threshold mode.
The receding timeout is not used in the window threshold
mode. The receding timeout elapses after the number of
conversion cycles equals 2
value of the four least significant bits of the timeout register.
TimeOutApr
, where TimeOutApr is the value of the four
TimeOutRec
TimeOutApr
Bits [7:4]
, where TimeOutRec is the
0x08
TimeOutRec
Bits [3:0]
0x06
Rev. 0 | Page 17 of 28
When either the approaching or receding timeout elapses (that
is, after the defined number of CDC conversions is counted),
the data average (and thus the thresholds) is forced to follow the
new CDC data value immediately.
When the timeout register equals 0, timeouts are disabled.
DATA AVERAGE
DATA AVERAGE
DATA AVERAGE
DATA AVERAGE
+ SENSITIVITY
+ SENSITIVITY
THRESHOLD
THRESHOLD
After a Large Change in CDC Data Away from Threshold
After a Large Change in CDC Data Toward Threshold
Figure 39. Threshold Timeout Approaching
Figure 40. Threshold Timeout Receding
AWAY FROM THE THRESHOLD
LARGE CHANGE IN DATA
TIMEOUT APPROACHING
TIMEOUT RECEDING
LARGE CHANGE IN DATA
TOWARDS THRESHOLD
TIME
TIME
AD7150