DK-SI-4SGX230N Altera, DK-SI-4SGX230N Datasheet

KIT DEV STRATIX IV 4SGX230N/C2

DK-SI-4SGX230N

Manufacturer Part Number
DK-SI-4SGX230N
Description
KIT DEV STRATIX IV 4SGX230N/C2
Manufacturer
Altera
Series
Stratix® IV GXr
Type
FPGAr
Datasheet

Specifications of DK-SI-4SGX230N

Contents
Board, Cables, CD, Power Supply
Silicon Manufacturer
Altera
Core Architecture
FPGA
Core Sub-architecture
Stratix
Silicon Core Number
EP4S
Silicon Family Name
Stratix IV GX
Rohs Compliant
Yes
For Use With/related Products
EP4SGX230
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
544-2592
DK-SI-4SGX230N/C2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DK-SI-4SGX230N
Manufacturer:
ALTERA
0
P30-38445-00
101 Innovation Drive
San Jose, CA 95134
www.altera.com
Transceiver Signal Integrity Development Kit,
Stratix IV GX Edition User Guide
Document Version:
Document Date:
December 2009
2.0

Related parts for DK-SI-4SGX230N

DK-SI-4SGX230N Summary of contents

Page 1

... Transceiver Signal Integrity Development Kit, 101 Innovation Drive San Jose, CA 95134 www.altera.com P30-38445-00 Stratix IV GX Edition User Guide Document Version: Document Date: 2.0 December 2009 ...

Page 2

... Altera warrants performance of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information, product, or service described herein except as expressly agreed to in writing by Altera Corporation ...

Page 3

... Link Statistics Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–6 PCI Express Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–6 Power and Temperature Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–6 Channel Reconfig Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–7 EyeQ Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–7 © February 2009 Altera Corporation Chapter 1. About This Kit Introduction 1–1 Transceiver Signal Integrity Development Kit, Stratix IV GX Edition User Guide Contents ...

Page 4

... About–1 Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . About–1 How to Contact Altera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . About–1 Typographic Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . About–2 ...

Page 5

... Stratix IV GX EP4SGX230 Signal Integrity Transceiver Development Board—a ■ development platform that allows you to develop and prototype hardware designs running on the Stratix IV GX FPGA (ordering code: DK-SI-4SGX230N). f For detailed information about board components and interfaces, refer to the Reference © ...

Page 6

... Ethernet CAT-5/RJ-45 cable ■ Power supply and AC adapters for North America, Japan, Europe, and the ■ United Kingdom Transceiver Signal Integrity Development Kit, Stratix IV GX Edition User Guide Chapter 1: About This Kit Kit Features ® II webserver © February 2009 Altera Corporation ...

Page 7

... Before You Begin Before using the kit or installing the software, check the kit contents and inspect the board to verify that you received all of the items listed in this section. If any of the items are missing, contact Altera before you proceed. Check the Kit Contents Refer to “ ...

Page 8

... Quartus II Programmer Quartus II Programmer System Requirements The Quartus II Programmer has some minimum system requirements. f For Quartus II Programmer system requirements, refer to the Altera website at: www.altera.com/products/software/products/quartus2web/sof- quarwebmain.html. References For other related information, refer to the following websites: For additional daughter cards available for purchase: ■ ...

Page 9

... Transceiver Signal Integrity Development Kit, Stratix IV GX Edition CD-ROM. Quartus II software—you do not need the Quartus II software for development kit ■ evaluation; however, Altera recommends you obtain the Quartus II software to create new designs. ■ USB-Blaster driver. Before starting the installation, verify that you have complied with the conditions described in “ ...

Page 10

... The Stratix IV GX transceiver signal integrity board includes integrated USB-Blaster circuitry for FPGA programming. However, for the host computer and signal integrity board to communicate, you must install the USB-Blaster driver on the host computer. To download the USB-Blaster driver the Altera support site at www.altera.com/support/software/drivers/dri-index.html. To install it blaster-xp.html. ...

Page 11

... After the board powers up, the on-board flash memory, which ships preprogrammed with the factory design, automatically configures the Stratix IV GX device. The FACTORY LED illuminates, signaling that the Stratix IV GX device is configured with the preprogrammed factory design. © February 2009 Altera Corporation 4. Development Board Setup SW2.1 SW2.2 ...

Page 12

... Transceiver Signal Integrity Development Kit, Stratix IV GX Edition User Guide Chapter 4: Development Board Setup Powering Up the Board © February 2009 Altera Corporation ...

Page 13

... Board Update Portal web page. The web page allows you to upload new FPGA designs to the designated user flash memory on your board, and also provides links to useful information, on the Altera website at www.altera.com, including links to kit-specific and design resources. After the Board Update Portal is used to successfully update a user design, jumper J62 can be set to LOAD USER and the user design configures upon reset or power up ...

Page 14

... The Board Update Portal allows remote update of new FPGA configurations to the user portion of the flash memory. Perform the following steps to update the user memory on your board with a design downloaded from the Altera website. 1. Type the IP address displayed on the LCD into the web browser on the PC or use the browser’ ...

Page 15

... Demonstration application as explained in Development Kit, Stratix IV GX Edition CD-ROM” on page Test Designs Altera provides a set of test designs for the evaluation of the Stratix IV GX device transceiver performance and board features. The .sof file names and data rates for each test design are listed in Quartus II Programmer to configure the Stratix IV GX device with one of the .sof files. Table 6– ...

Page 16

... Transceiver Signal Integrity Development Kit, Stratix IV GX Edition User Guide Chapter 6: Stratix IV GX Transceiver Signal Integrity Demonstration “LCD Information” for more information. Table 6–1 on page 6–1. (Figure ® LCD Information 6–1). II Embedded Logic Analyzer, Table 6–1 on © February 2009 Altera Corporation ...

Page 17

... Select the VCCHTX value based on the jumper (J11) settings. Similarly, ensure that the VCCA_L/R supply jumper (J6) is connected according the settings shown in © February 2009 Altera Corporation Table 6–2. Transceiver Signal Integrity Development Kit, Stratix IV GX Edition User Guide 6– ...

Page 18

... Pins 2 and 3 Description differential output driver voltage. equalization. DC gain. preemphasis/deemphasis. pre, 1stpost, and 2ndpost settings represent different taps. Description Reset for the transceiver. Reset for all the error counters to zero. Jumper Header Connection VCCA_L/R (Volt) 3.0 V © February 2009 Altera Corporation ...

Page 19

... PRBS/CJTPAT data. Data verifiers are not available for the high frequency (1010..) and low frequency (5’1s and 5’0s) patterns. © February 2009 Altera Corporation Description You can manually change the preemphasis and equalization to observe the setting that provides an error free link ...

Page 20

... Transceiver Signal Integrity Development Kit, Stratix IV GX Edition User Guide Chapter 6: Stratix IV GX Transceiver Signal Integrity Demonstration Running the Demonstration Application and Test Designs Description 0: –6 db; 1: –3.5 db 0–7 © February 2009 Altera Corporation ...

Page 21

... Automatic—Automatically sequences through the phase steps 0-31, plots the value, and records the BER information for each phase step in a .csv format. © February 2009 Altera Corporation “LCD Information” on page chapter in volume 2 of the Stratix IV Device Handbook. ...

Page 22

... Eye opening ( unit interval 1/32 * 100 +/- 3%, where N is the number of phase steps with no errors. Transceiver Signal Integrity Development Kit, Stratix IV GX Edition User Guide Chapter 6: Stratix IV GX Transceiver Signal Integrity Demonstration Running the Demonstration Application and Test Designs © February 2009 Altera Corporation ...

Page 23

... Board Update Portal. These software files were created using the Nios II EDS just as the hardware design was created using the Quartus II Design application. f For more information about Altera development tools, refer to www.altera.com/products/software/sfw-index.jsp. Parallel Flash Loader The development kit features a MAX II configuration design in the <install dir> ...

Page 24

... If you have hardware developed using the Quartus II application, and software developed using the Nios II EDS, follow these instructions the Windows Start Menu All Programs> altera> Nios II EDS> Nios II Command Shell the Nios II Command Shell, navigate to the directory where your design files are located and type the following Nios II EDS commands: For ...

Page 25

... LEDs flash repeatedly on and off indicating that the flash device is ready for programming. Secondly, run the Nios II EDS nios2-flash-programmer the Windows Start Menu All Programs> altera> Nios II EDS> Nios II Command Shell the Nios II Command Shell, navigate to the <install dir> ...

Page 26

... LEDs flash repeatedly on and off indicating that the flash device is ready for programming the Windows Start Menu All Programs> altera> Nios II EDS> Nios II Command Shell the Nios II Command Shell, navigate to the <install dir> ...

Page 27

... MAC address ensure that you have the most up-to-date factory restore files and information about this product the Altera website at www.altera.com/products/devkits/kit-dev_platforms.jsp. © February 2009 Altera Corporation Transceiver Signal Integrity Development Kit, Stratix IV GX Edition User Guide ...

Page 28

... A–6 Transceiver Signal Integrity Development Kit, Stratix IV GX Edition User Guide Appendix A: Programming the Flash Device Restoring the Factory Design to the Flash Device © February 2009 Altera Corporation ...

Page 29

... Contact Technical support Technical training Product literature Non-technical support (General) Email (Software Licensing) Email Note to Table: (1) You can also contact your local Altera sales office or sales representative. © February 2009 Altera Corporation Changes Made Contact (Note 1) Method Website www.altera.com/support Website www ...

Page 30

... A warning calls attention to a condition or possible situation that can cause you injury. The angled arrow instructs you to press Enter. The feet direct you to more information about a particular topic. Additional Information Typographic Conventions © February 2009 Altera Corporation ...

Related keywords