M3062PT3-CPE User’s Manual
2.7 Self-check
2.7.1 Self-check Procedure
To run the self-check of the emulator, do so as explained here below. While the self-check is in progress, the LEDs will change
as shown in Figure 2.11.
(1) If the user system is connected, disconnect it.
(2) Set the switches as the factory-settings to execute the self-check (see Table 2.4).
(3) Within 2 seconds of activating power to the emulator, press the system reset switch on the emulator upper panel.
(4) Check the SAFE LED starts flashing and then press the system reset switch again.
(5) The self-check will start. If the normal result is displayed in about 20 seconds, the self-check terminated normally.
Table 2.4 Switch settings for the self-check
Figure 2.11 Self-check procedure
REJ10J1007-0400 Rev.4.00 July 29, 2009
MCU power supply source selection jumper (JP1)
MCU power supply voltage selection jumper (JP2)
VCC1, VCC2 power selection jumper (JP1 of the
M3062PT2-EPBM)
POWER
POWER
POWER
POWER
LED 3
LED 3
LED 3
LED 3
Switch
CLOCK
Blinking
LED 4
CLOCK
CLOCK
CLOCK
LED 4
LED 4
LED 4
RESET
RESET
LED 5
RESET
RESET
LED 5
LED 5
LED 5
LED 6
RUN
LED 6
LED 6
RUN
LED 6
RUN
RUN
SAFE LED status
Normal
ON
POWER
POWER
POWER
POWER
Self - check starts .
LED 1
LED 1
LED 1
LED 1
VCC1=2
Setting
SAFE
SAFE
LED 2
SAFE
SAFE
LED 2
LED 2
LED 2
INT
5V
It takes 10 seconds at XIN = 16 MHz .
OFF
POWER
LED 3
(3 ) Target status LEDs start blinking at random intervals .
LEDs start blinking according to the error type
SAFE LED is turned off and one or more target status
RESET
RESET
CLOCK
LED 4
ON
(1 ) Within 2 seconds of activating power ,
(2) Check that the SAFE LED starts
RESET
LED 5
blinking, then press the system reset
switch again.
press the reset switch .
LED display
Blinking
RUN
LED 6
Error
OFF
POWER
LED 1
.
SAFE
LED 2
Page 31 of 108
2. Setup

Related parts for M3062PT3-CPE