ZGP32300100ZPR Zilog, ZGP32300100ZPR Datasheet

PROGRAMMING SYSTEM Z8 GP ZGP323

ZGP32300100ZPR

Manufacturer Part Number
ZGP32300100ZPR
Description
PROGRAMMING SYSTEM Z8 GP ZGP323
Manufacturer
Zilog
Series
Z8 GP™r
Type
Ethernetr
Datasheet

Specifications of ZGP32300100ZPR

Contents
Programmer, Power Supply, Cable(s) and Software
Positions/sockets
1
Description/function
Z8 GP ZGP323 Programming Sytem
For Use With/related Products
Z8 GP ZGP323
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
269-3390
ZGP32300100ZPR
Z8 GP™ ZGP323
Programming System
User Manual
UM017403-0707
Zilog
Copyright ©2007 by
, Inc. All rights reserved.
www.zilog.com

Related parts for ZGP32300100ZPR

ZGP32300100ZPR Summary of contents

Page 1

... ZGP32300100ZPR Z8 GP™ ZGP323 Programming System User Manual UM017403-0707 Zilog Copyright ©2007 by , Inc. All rights reserved. www.zilog.com ...

Page 2

... Each instance in Revision History reflects a change to this document from its previous revision. For more details, refer to the corresponding pages and appropriate links in the table below. Date July 2007 Revision History Revision Level Description 03 Updated document with latest company address and implemented Zilog Style Guide. Page No All UM017403-0707 ...

Page 3

Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

Page 4

... Zilog’ family of microcontrollers. A windowed 28-CDIP chip is included for use in prototyping. This User Manual guides in connecting the programming system compo- nents to your PC, and a target board, install the Zilog Developer Studio II (ZDS II) and use ZDS II to burn demonstration code into family OTP microcontroller. ...

Page 5

... You may have an updated version. 4. The following directory is installed on the host PC, assuming all installation settings remain at their defaults: C:\Program Files\ZiLOG\ZDSII_<product>_<version number> Hardware Installation The Z8 GP features an Ethernet interface and an RS-232 console port. You may have to configure the network settings. ...

Page 6

Figure 1. Hardware Setup Using the Supplied Crossover Cable Follow the steps in this section to install the Z8 GP ZGP323 Program- ming System and to configure the Z8 Programmer, see ence. 1. Use the 40-circuit ribbon cable to connect ...

Page 7

Hardware Configuration The default IP address and subnet mask of the Z8 Programmer module are 192.168.1.50 and 255.255.255.0, respectively. To enable communication between the PC running ZDS II and the Z8 Programmer, you must either change the PC’s Ethernet settings ...

Page 8

Follow the steps below to change the PC’s settings: 1. Open the Windows Control Panel and double-click the Network and Internet Connections icon, see UM017403-0707 Z8 GP™ ZGP323 Programming System Figure 2. Network Connections User Manual Figure 2. Introduction 5 ...

Page 9

In the panel labeled LAN or High-Speed Internet, double-click the Local Area Connection icon. The Local Area Connection Status window appears, see Figure 3. Local Area Connection Status Window UM017403-0707 Z8 GP™ ZGP323 Programming System Figure 3. User Manual ...

Page 10

In the Local Area Connection Status window, click Properties but- ton. The Local Area Connection Properties dialog box appears, see Figure 4. Figure 4. Local Area Connection Properties Dialog Box UM017403-0707 Z8 GP™ ZGP323 Programming System User Manual 7 ...

Page 11

Select Internet Protocol (TCP/IP) from the scroll down list, and click Properties button. The Internet Protocol (TCP/IP) Properties dialog box appears, see Figure 5. Internet Protocol Properties Dialog UM017403-0707 Z8 GP™ ZGP323 Programming System Figure 5. User Manual 8 ...

Page 12

Enter an IP address of 192.168.1.21 and a subnet mask of 255.255.255.0. These values connect the the same network as the Z8 Programmer unit, and do not conflict with the IP address of Z8 Programmer. 6. ...

Page 13

... ZiLOG TCP/IP Software Suite v1.1 Copyright (C) 2004 ZiLOG Inc. All Rights Reserved clock enabled IP Address: 192.168.1.50 IP Subnet: 192.168.1.0/255.255.255.0 IP Gateway: 192.168.1.254 Z8 Programmer Firmware x.x Copyright (C) 2001-2004 ZiLOG, Inc. All Rights Reserved. Press 'Ctl-Z' to enter configuration mode 7. Press ctrl-z eth1% Note: The Z8 Programmer console prompt is not case-sensitive. ...

Page 14

... ZGP323 28-CDIP chip via the OTP programming module. The sample project directory, located in: c:\Program Files\ZiLOG\ZDSII_<product>_<version> \samples\<processor type>_<demo name> \<demo name>_<language>\src 1. Start ZDS II for the Z8 GP ZGP323 programming system by selecting Start – ...

Page 15

Set the Output Files Directory specific directory where the out- put files will be stored. By default, ZDS II stores the files in the same directory as the project files the Debugger tab, set the ...

Page 16

Connect the Z8 GP ZGP323 programming system to your develop- ment PC as described in 17. Select Project –> Settings to open the Project Settings window. 18. In the Debugger tab of the Project Settings window, select Ethernet Driver ...

Page 17

Figure 6. OTP Programming Window (Hex File Example) 25. Select the appropriate target device from the Device drop-down menu. 26. In the Hex File: section, click programmed on to the OTP chip. UM017403-0707 Z8 GP™ ZGP323 Programming System button and ...

Page 18

If you do not want to pad the hex file, select the None button in the Pad File With panel. Otherwise, select FF, 00, or Other button. If you select the Other button, type the hex value to pad ...

Page 19

Appendix A–Z8 GP ZGP323 Programmer Interface Commands Table 2 describes the Z8 GP ZGP323 Programmer Interface Commands. Table ZGP323 Programmer Interface Commands Command ? debugport devs exit help UM017403-0707 Z8 GP™ ZGP323 Programming System Description and Options ...

Page 20

Table ZGP323 Programmer Interface Commands (Continued) Command ifconfig kbuf kill mem password ps reboot restore UM017403-0707 Z8 GP™ ZGP323 Programming System Description and Options Configures the Z8 Programmer network interface. Entering ipconfig with no options lists current ...

Page 21

... Customer Support For answers to technical questions about the product, documentation, or any other issues with Zilog’s offerings, please visit Zilog’s Knowledge Base at http://www.zilog.com/kb. For any comments, detail technical questions, or reporting problems, please visit Zilog’s Technical Support at http://support.zilog.com. ...

Page 22

... TECHNOLOGY DESCRIBED HEREIN OR OTHERWISE. The information contained within this document has been verified according to the general principles of electrical and mechanical engineering and Crimzon are the trademarks or the registered trademarks of Zilog, Inc. All other product or service names are the property of their respective owners. UM017403-0707 Z8 GP™ ...

Related keywords