HS7750KCI01H Renesas Electronics America, HS7750KCI01H Datasheet - Page 224

no-image

HS7750KCI01H

Manufacturer Part Number
HS7750KCI01H
Description
ON CHIP DEBUG EMULATOR
Manufacturer
Renesas Electronics America
Datasheets

Specifications of HS7750KCI01H

Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
2. Notes on Setting the [Trace Acquisition] Window
6.5.6
1. Errors
Rev. 2.0, 01/01, page 200 of 214
(1) When the [Acquire continuous trace] check box is selected, do not perform memory access
(2) When internal I/O trace or LDTLB instruction trace is performed, select the [Acquire
(3) When the [Acquire continuous trace] check box is selected, 32 trace information data can
(4) Trace information cannot be acquired for the following branch instructions:
(5) When the [Acquire continuous trace] check box is selected, and when either the [Get trace
(6) In the SH7750 E10A emulator, the contents of the SGR register are lost when the user
(7) When continuous trace is used, do not enable user interrupt by the INTERRUPT command
The profile function internally breaks user program execution, collects the measured data, and
re-executes the user program.
Since the function also counts when the measured item is generated at break or re-execution,
an error will be included in the measured profile value.
The measured value of this function should be the target.
during emulation.
continuous trace] check box.
be acquired. In this case, however, since the user program stops at constant intervals, the
processing speed is decreased compared with the case where the [Acquire continuous trace]
check box is not selected.
information of internal I/O area] radio button (internal I/O trace enabled) or the [Get trace
information of LDTLB instruction] radio button is selected (LDTLB instruction trace
enabled) with the [Break Condition 5] dialog box,
program breaks. Since the user program execution stops at constant intervals while the
continuous trace is selected, the contents of the SGR register will be lost. Accordingly, do
not use the continuous trace for a program in which an SGR value is referred to with the
interrupt handler.
during the emulator command wait state or user program execution.
Notes on Using the Profile Function
The BF and BT instructions whose displacement value is 0
Branch to H'A0000000 by reset
An internal I/O trace cannot be made with the Step In command.
The LDTLB instruction and internal I/O trace cannot be performed with the Step Over
command.